Stability Experiments with Hydrodynamic Tilted-Lobe Journal Bearings of Various Numbers of Lobes and Length-to-Diameter Ratios
Author:
- 1 January 1977
- journal article
- research article
- Published by Taylor & Francis in A S L E Transactions
- Vol. 20 (4) , 271-281
Abstract
Hydrodynamic journal bearing stability tests were conducted with 3.8 centimeter (1.5 in) diameter tilted-lobe bearings. The bearings had 3, 5, and 7 lobes and L/D ratios from 0.2 to 1.0. They were tested in water and MIL-L-7808G oil at 294 K (70 F) at speeds to 5, 400 rpm with zero load. Stability was not appreciably affected by the number of lobes and decreased with a decrease in L/D ratio. However, a three-tilted-lobe bearing with an offset factor of 0. 76 and an L/D of 0.5 was more stable than a three-centrally-lobed bearing with an offset factor of 0.50 and an L/D of 1.0. All data can be presented in terms of the parameter[Mbar](Γ*)1.4 = 9, where[Mbar]is the dimensionless mass parameter and Γ* is the optimized stability parameter.Keywords
This publication has 1 reference indexed in Scilit:
- Low-Cost Fluid Film Bearings for Gas Turbine EnginesSAE International Journal of Advances and Current Practices in Mobility, 1972