Secure Loss of Excitation Detection Method for Synchronous Generators During Power Swing Conditions
- 7 June 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (4) , 1907-1916
Abstract
Conventional loss of excitation (LOE) detection methods for synchronous generators may misoperate in the case of power swings. In this paper, a novel method based on measured slip frequency at the terminal of synchronous generators is proposed to differentiate power swing conditions from LOE condition. To enhance the performance of the proposed method for the noisy measured signals, a modified Prony method based on combination of generalized total least-squares (GTLS) method and conventional Prony method is implemented to estimate the slip frequency and an energy sorting technique is applied to distinguish the dominant frequency component of the measured signals. The performance of the proposed method is evaluated under various operating conditions of a test system that is simulated in a co-simulation platform by linking CAPE and PSS/E software. Case study results illustrate that the proposed method can accurately differentiate the power swing condition from LOE condition.Keywords
Funding Information
- National Science Foundation (NSF-EEC-9908690)
This publication has 32 references indexed in Scilit:
- A Novel Approach to Detect the Synchronous Generator Loss of ExcitationIEEE Transactions on Power Delivery, 2014
- Identification of generator loss‐of‐excitation from power‐swing conditions using a fast pattern classification methodIET Generation, Transmission & Distribution, 2013
- Variable-Frequency Prony Method in the Analysis of Electrical Power QualityMetrology and Measurement Systems, 2012
- Estimation of frequency components in stator current for the detection of broken rotor bars in induction machinesMeasurement, 2010
- Parameter estimation for exponential sums by approximate Prony methodSignal Processing, 2010
- Adaptive Prony method for waveform distortion detection in power systemsInternational Journal of Electrical Power & Energy Systems, 2007
- Initial Results in Power System Identification From Injected Probing Signals Using a Subspace MethodIEEE Transactions on Power Systems, 2006
- Excitation system protective limiters and their effect on volt/VAr control-design, computer modeling, and field testingIEEE Transactions on Energy Conversion, 2000
- Underexcitation limiter models for power system stability studiesIEEE Transactions on Energy Conversion, 1995
- ANN based pattern classification of synchronous generator stability and loss of excitationIEEE Transactions on Energy Conversion, 1994