Non-Contact SpO2 Estimation Using Camera-Based Photoplethysmography: A Machine Learning Approach on Edge
Open Access
Abstract
Vital signs monitoring, particularly of patients with infectious diseases, is crucial for clinical care. Traditional contact-based tools pose risks of cross-contamination and discomfort, especially for individuals with fragile skin. This study introduces a novel non-contact system for real-time peripheral oxygen saturation (SpO2) monitoring using an (RGB) camera. The proposed algorithm combines the ratio of ratios (RoR) method with machine learning techniques (Elastic Net, Ridge, and Linear Regression). The data of 98 patients were collected in a real-world setting: 65 were used for model development and selection through 10-fold cross-validation, 15 for intercept calibration, and 18 for final evaluation. The method achieved a mean absolute error (MAE) of 0.89% and a Root Mean Square Error (RMSE) of 1.20% compared to conventional methods during the final evaluation. The algorithm is specifically designed for deployment in embedded architectures. For this reason, it was implemented on three different embedded platforms and on a PC to choose the most suitable architecture based on the latency, FPS, the execution time, the peak RAM usage, the average CPU utilization and the average CPU temperature.Keywords
This publication has 30 references indexed in Scilit:
- A Deep Neural Network Based on Two‐Stage Training for Estimating Heart Rate Variability From Camera VideosHealth Care Science, 2026
- Privacy-Aware Monitoring for Assisted Living2025
- Innovative approaches in imaging photoplethysmography for remote blood oxygen monitoringScientific Reports, 2024
- An integrated and real-time social distancing, mask detection, and facial temperature video measurement system for pandemic monitoringJournal of Real-Time Image Processing, 2023
- A non-contact oxygen saturation detection method based on dynamic spectrumInfrared Physics & Technology, 2022
- Noncontact Imaging Plethysmography for Accurate Estimation of Physiological ParametersJournal of Medical and Biological Engineering, 2017
- An efficient algorithm of ECG signal denoising using the adaptive dual threshold filter and the discrete wavelet transformBiocybernetics and Biomedical Engineering, 2016
- Noncontact simultaneous dual wavelength photoplethysmography: A further step toward noncontact pulse oximetryReview of Scientific Instruments, 2007
- Contactless Multiple Wavelength Photoplethysmographic Imaging: A First Step Toward “SpO2 Camera” TechnologyAnnals of Biomedical Engineering, 2005
- Untersuchungen über die Sauerstoffsättigung des menschlichen ArterienblutesNaunyn-Schmiedeberg's Archives of Pharmacology, 1935