Three-dimensional Laparoscopy
- 1 August 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Surgical Laparoscopy, Endoscopy & Percutaneous Techniques
- Vol. 25 (4) , 321-323
Abstract
Purpose: Complex laparoscopy is difficult to master because it involves 3-dimensional (3D) interpretation on a 2-dimensional (2D) viewing screen. The use of 3D technology has an uncertain effect on training surgeons. We aim to evaluate the effectiveness of 3D on learning and performing laparoscopic tasks. Methods: Medical students without laparoscopic experience (novices) were evaluated doing inanimate object transfer and laparoscopic suturing. Tasks were repeated using 2D and 3D cameras with standard instruments. Time and error rates (missed attempts, dropped objects, and failure to complete the task) were recorded. Results: Twenty-nine novice medical students experienced a 45.5% decrease in the time to complete PEG transfer using 3D (mean 207 s with 2D vs. 113 s with 3D). Error rate was reduced to 50% (2D, 4 errors vs. 3D, 2 errors) and mean drop rate was reduced to 0. Similar decreases in suture time (46.5%) were seen (mean 403 s with 2D vs. 220 s with 3D). Conclusions: Our results indicate that 3D significantly improved visualization and ability to perform complex tasks in the skills laboratory setting. This technology may be very effective in teaching advanced laparoscopic skills in the era of work-hour restrictions.Keywords
This publication has 14 references indexed in Scilit:
- Advanced stereoscopic projection technology significantly improves novice performance of minimally invasive surgical skillsSurgical Endoscopy, 2012
- 3D HD versus 2D HD: surgical task efficiency in standardised phantom tasksSurgical Endoscopy, 2011
- New Technology and Health Care Costs — The Case of Robot-Assisted SurgeryNew England Journal of Medicine, 2010
- A comparison of laparoscopic and robotic assisted suturing performance by experts and novicesSurgery, 2010
- Objective assessment of technical surgical skillsBritish Journal of Surgery, 2010
- A computerized assessment to compare the impact of standard, stereoscopic, and high-definition laparoscopic monitor displays on surgical techniqueSurgical Endoscopy, 2010
- Comparison of two- and three-dimensional camera systems in laparoscopic performance: a novel 3D system with one cameraSurgical Endoscopy, 2009
- Reducing the unexpectedly high rate of injuries caused by NOTES gastrotomy creationSurgical Endoscopy, 2009
- Prospective, Randomized, Double-Blind Trial of Curriculum-Based Training for Intracorporeal Suturing and Knot TyingJournal of the American College of Surgeons, 2008
- Evaluation of the Learning Curve in Laparoscopic Colorectal SurgeryAnnals of Surgery, 2005