Experimental Determination of the Limiting Criteria for Human Exposure to Low Winter Humidity Indoors (RP-1160)
Authors:
- David P. WyonDWDavid P. Wyon
- Lei FangLFLei Fang
- Love LagercrantzLLLove Lagercrantz
- 1 April 2006
- journal article
- research article
- Published by Taylor & Francis in HVAC&R Research
- Vol. 12 (2) , 201-213
Abstract
Thirty subjects (17 female) were exposed for five hours in a climate chamber at 22°C (71.6°F) to clean air at 5%, 15%, 25%, and 35% RH. A comparable group was similarly exposed to air polluted by carpet and linoleum to the 35% RH condition and to 18°C, 22°C, and 26°C (64.4°F, 71.6°F, and 78.8°F) at an absolute humidity equal to 15% RH at 22°C (71.6°F). They performed simulated office work to ensure that they kept their eyes open and reported sick building syndrome (SBS) symptom intensity on visual-analogue scales. Nine objective tests of eye, nose, and skin function were applied. Subjective discomfort, though significantly increased by low humidity, was slight even at 5% RH. More rapid blink rates were observed at 5% than at 35% RH (P < 0.05), and tear film quality as indicated by the Mucous Ferning Test deteriorated (P < 0.05) at low humidity (5%, 15%) and at the highest air temperature 18°C, 22°C > 26°C (78.8°F). Low humidity was found to have reduced the rate of performance of three office tasks by 3%–7%.Keywords
This publication has 16 references indexed in Scilit:
- Eye complaints in the office environment: precorneal tear film integrity influenced by eye blinking efficiencyOccupational and Environmental Medicine, 2004
- Low Relative Humidity and Aircraft Cabin Air QualityIndoor Air, 2001
- Impact of Temperature and Humidity on Perception of Indoor Air Quality During Immediate and Longer Whole-Body ExposuresIndoor Air, 1998
- Impact of Temperature and Humidity on the Perception of Indoor Air QualityIndoor Air, 1998
- Effect of air humidification on the sick building syndrome and perceived indoor air quality in hospitals: a four month longitudinal study.Occupational and Environmental Medicine, 1994
- Indoor Air Humidity And Sensation Of Dryness As Risk Indicators Of SbsIndoor Air, 1993
- Sick buildings and the experimental approachEnvironmental Technology, 1992
- The importance of the precorneal tear film for the quality of optical imaging.British Journal of Ophthalmology, 1992
- The Effect of Air Humidification on Symptoms and Perception of Indoor Air Quality in Office Workers: A Six-Period Cross-Over TrialArchives of Environmental Health: An International Journal, 1992
- Measurement of acute response to draught in the eyeActa Ophthalmologica, 1987