A Simple Pre-Operative Nuclear Classification Score (SPONCS) for Grading Cataract Hardness in Clinical Studies
Open Access
- 29 October 2020
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (11) , 3503
Abstract
Background: The aim of this study was to evaluate whether a simplified pre-operative nuclear classification score (SPONCS) was valid, both for clinical trials and real-world settings. Methods: Cataract classification was based on posterior nuclear color: 0 (clear), 1 (subcapsular/posterior cataract with clear nucleus), 2 (mild “green nucleus” with plus sign for yellow reflection of the posterior cortex), 3 (medium “yellow nucleus” with plus sign for brown/red posterior cortex reflection), 4 (advanced with 4 being “red/brown nucleus” and 4+ white nucleus), and 5 (hypermature/Morgagnian nucleus). Inter- and intra-observer validity was assessed by 30 Ophthalmologists for 15 cataract cases. The reliability of the cataract grading score in a surgical setting was evaluated. Correlation of nuclear scores was compared with phacoemulsification cumulative dissipated energy (CDE) in 596 patients. Results: Analysis of mean intra-observer Cohen kappa agreement was 0.55 with an inter-observer score of 0.54 for the first assessment and 0.49 for the repeat assessment one week later. When evaluating results by nuclear color alone, there was a substantial agreement for both the intra-observer (0.70) and inter-observer parameters: 0.70 for the first test, and 0.66 on repetition with randomization of the cases after a week. CDE levels were found to be significantly different between all SPONCS score groups (p < 0.001), with a lower CDE related to a lower SPONCS score. A strong correlation was found between the SPONCS score and CDE (Spearman′s rho = 0.8, p < 0.001). Conclusion: This method of grading cataract hardness is both simple and repeatable. This system can be easily incorporated in randomized controlled trials to lower bias and confounding effects regarding nuclear density along with application in the clinical setting.Keywords
This publication has 16 references indexed in Scilit:
- Impact of lens densitometry on phacoemulsification parameters and usage of ultrasound energy in femtosecond laser-assisted lens surgeryCanadian Journal of Ophthalmology, 2017
- Automatic Feature Learning to Grade Nuclear Cataracts Based on Deep LearningIEEE Transactions on Biomedical Engineering, 2015
- The changing fate of the corneal endothelium in cataract surgeryCurrent Opinion in Ophthalmology, 2012
- Clinical application of the lens Opacities Classification System III in the performance of phacoemulsificationJournal of Cataract & Refractive Surgery, 2003
- A simplified cataract grading system The WHO Cataract Grading GroupOphthalmic Epidemiology, 2002
- The Lens Opacities Classification System IIIArchives of Ophthalmology (1950), 1993
- Classification System for CataractsOphthalmic Research, 1990
- Lens Opacities Classification SystemArchives of Ophthalmology (1950), 1988
- The Oxford Clinical Cataract Classification and Grading SystemInternational Ophthalmology, 1986