Abstract
Objective. Ozone (O3) has been suggested as an anti-microbial treatment in dentistry, with an ozone gas delivery system introduced for the treatment of fissure and root caries. The aim of this study was to investigate the sealing capacity of the novel delivery system and its re-suction capacity during accidental displacement of the cup at different stages of ozone delivery. Material and methods. Ozone leakage was studied in vitro after application on a flat metal surface and on buccal and occlusal tooth surfaces. An ozone analyzer was used to measure ozone gas concentrations adjacent to the delivering cups when adapted to the target surfaces during and after 10–20 s application cycles. The measured levels were compared with the background concentrations in the room. Measurements were performed 1) after complete ozone application cycles, 2) within the cycle before the start of the suction period, and 3) after displacements of the cup during the cycles. Results. Ozone air values varied between 8 and 166 µg·m−3 for the flat metal surface and between 0 and 108 µg·m−3 for the tooth surfaces. Ozone leakage levels were 7.6 µg·m−3 for the flat and 7.4 µg·m−3 and 5.6 µg·m−3 for the buccal and occlusal surfaces, respectively, and 5.2 µg·m−3 and 9.8 µg·m−3 for the premolar and molar surfaces, respectively. Cycles with displacement showed significantly higher leakage levels than continuous complete cycles (p=0.03). Conclusions. Ozone application cycles with displacements showed significantly higher leakage levels than continuous complete cycles. The largest ozone delivery cups showed the highest leakage values. A change in background levels was seen with similar change in adjacent ozone levels. The overall measured ozone leakage values were low after normally functioning delivery cycles and after repeated displacements. The delivery system can be considered safe.Keywords
This publication has 13 references indexed in Scilit:
- Assessment of the safety of two ozone delivery devicesJournal of Dentistry, 2007
- Pulmonary Epithelial Integrity in Children: Relationship to Ambient Ozone Exposure and Swimming Pool AttendanceEnvironmental Health Perspectives, 2004
- Clara cell protein as a biomarker for ozone-induced lung injury in humansEuropean Respiratory Journal, 2003
- Clinical reversal of root caries using ozone, double‐blind, randomised, controlled 18‐month trialGerodontology, 2003
- Microbiological Evaluation of a Range of Disinfectant Products To Control Mixed-Species Biofilm Contamination in a Laboratory Model of a Dental Unit Water SystemApplied and Environmental Microbiology, 2003
- Recolonisation pattern of mutans streptococci after suppression by three different modes of chlorhexidine gel applicationEuropean Journal of Oral Sciences, 1999
- Hidden caries: What is it? Does it exist? Does it matter?International Dental Journal, 1997
- Ozone-induced mediator release from human bronchial epithelial cells in vitro and the influence of nedocromil sodiumEuropean Respiratory Journal, 1996
- Disinfection of Removable Dentures Using OzoneDental Materials Journal, 1996
- Ultrastructure, Growth, and Adherence of Streptococcus mutans after Treatment with Chlorhexidine and FluorideCaries Research, 1988