Comparison of three non‐invasive quantitative measurement systems for the pivot shift test
- 5 January 2012
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 20 (4) , 692-697
Abstract
Purpose: The purpose of this study was to evaluate three different non‐invasive measuring devices for the pivot shift phenomenon with reference to direct bony movement measured by an electromagnetic device rigidly attached to the tibia and femur.Methods: A lower body cadaveric specimen was prepared to create a positive pivot shift in both knees. Twelve expert knee surgeons from worldwide performed their preferred pivot shift technique three times in each knee. After watching an instructional video, the examiners used a standardized technique to perform three additional pivot shift maneuvers in each knee. An electromagnetic tracking system, rigidly attached to femur and tibia, was used to provide reference measurements during the pivot shift test. Three different devices were correlated to the reference method and evaluated in this study: (1) Electromagnetic tracking system with skin sensors; (2) Triaxial accelerometer system; (3) Simple image analysis.Results: When results from both pivot shift techniques (preferred and standardized) were combined, the electromagnetic tracking system with skin sensors showed positive correlation with the reference measurement for acceleration and translation parameters (r = 0.88 and r = 0.67, respectively; both P < 0.01); The triaxial accelerometer system demonstrated good correlation with the reference measurement for acceleration (r = 0.75; P < 0.001). The image analysis system was poorly correlated to the translation of the reference measurement (r = 0.24; P < 0.01).Conclusion: The electromagnetic tracking system with skin sensors provided the best correlation with the reference method. The triaxial accelerometer showed also a good correlation and the image analysis system showed a positive, but poor correlation with the reference method. More research is needed in order to validate simple and non‐invasive devices for clinical application.Keywords
This publication has 28 references indexed in Scilit:
- Similarities and Differences of Diagnostic Manual Tests for Anterior Cruciate Ligament InsufficiencyThe American Journal of Sports Medicine, 2011
- Feature selection using a principal component analysis of the kinematics of the pivot shift phenomenonJournal of Biomechanics, 2010
- A prospective randomised study of anatomical single-bundle versus double-bundle anterior cruciate ligament reconstruction: quantitative evaluation using an electromagnetic measurement systemInternational Orthopaedics, 2010
- Pivot‐shift test: Analysis and quantification of knee laxity parameters using a navigation systemJournal of Orthopaedic Research, 2009
- In Vivo Measurement of the Pivot-Shift Test in the Anterior Cruciate Ligament—Deficient Knee Using an Electromagnetic DeviceThe American Journal of Sports Medicine, 2007
- Reliability and Usefulness of a New In Vivo Measurement System of the Pivot ShiftClinical Orthopaedics and Related Research, 2007
- The Accuracy of the Clinical Examination in the Setting of Posterior Cruciate Ligament InjuriesThe American Journal of Sports Medicine, 1994
- Evaluation of Acute Traumatic Hemarthrosis of the Knee JointSouthern Medical Journal, 1990
- Untersuchung des KniegelenksZeitschrift für Orthopädie und ihre Grenzgebiete, 1988
- The Lateral Pivot ShiftClinical Orthopaedics and Related Research, 1980