Analysis of volume distribution of power loss in ferrite cores
- 22 March 2011
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 109 (7) , 07D308
Abstract
We present a technique to estimate the inhomogeneities of magnetic loss across the section of ferrite cores under ac excitation. The technique is based on two distinct calorimetric methods that we presented elsewhere. Both methods are based on the measurement of the rate of increase of the sample temperature under adiabatic condition. The temperature ramp is recorded either measuring the sample bulk resistivity or using a platinum probe pasted on the sample surface. As an example we apply the procedure to an industrial sample of Mn–Zn ferrite under controlled sinusoidal excitation with a peak induction of 50 mT in the range between 100 kHz and 2 MHz. The results are discussed by comparison with simulations of the dissipation field profile through the sample, calculated using a finite element method (FEM) code.Keywords
All Related Versions
This publication has 6 references indexed in Scilit:
- Comparison of Losses Measurement in a Ferrite With Two Calorimetric MethodsIEEE Transactions on Magnetics, 2010
- Permeability and losses in ferrites from dc to the microwave regimeJournal of Applied Physics, 2009
- Measurement of magnetic losses by thermal method applied to power ferrites at high level of induction and frequencyReview of Scientific Instruments, 2009
- Summary of losses in magnetic materialsIEEE Transactions on Magnetics, 2002
- Iron loss analysis of Mn-Zn ferrite coresIEEE Transactions on Magnetics, 1997
- 100 KHz-10 MHz iron loss measuring systemIEEE Transactions on Magnetics, 1987