Corrosion behavior and microhardness of three amalgams
Authors:
- 1 August 1988
- journal article
- research article
- Published by Wiley in European Journal of Oral Sciences
- Vol. 96 (4) , 376-383
Abstract
The marginal microhardness of three different types of analgam was tested after 2 months'' immersion in an aqueous solution of NaCl (85 mM) and phosphates (Na2HPO4 100 mM and NaH2PO4 100 mM). Amalgams immersed in distilled water were used as controls. The microhardness tests were conducted at a distance of 50 .mu.m from the margins and at the bulk of each specimen. The solutions were analyzed for Sn, Cu, Zn, Ag, and Hg by means of atomic absorption spectrophotometry (AAS). A statistically significant reduction in the marginal microhardness after immersion in the test solution was found for the conventional and the high-Cu single composition amalgam but not for the high-Cu blended amalgam. SEM-examination of cross-sections of the amalgams revealed small areas of subsurface grain boundary corrosion, no deeper than 10 .mu.m for all the amalgams. The SEM-examination of the specimens and AAA analysis of the solutions indicated that the reduction in marginal microhardness was attributed mainly to corrosion of the Cu-rich phases for the high-Cu single composition amalgam and to corrosion of the .gamma.2 phase for the conventional amalgam. The phosphates reduced the corrosion of the amalgams in the presence of NaCl. It is concluded that the marginal strength of dental amalgams in a corrosive environment is largely dependent upon their corrosion ressitance.Keywords
This publication has 14 references indexed in Scilit:
- Creep versus marginal fracture of amalgam restorationsJournal of Oral Rehabilitation, 1986
- Fracture toughness determination of dental amalgams through microindentationJournal of Biomedical Materials Research, 1986
- The role of phosphate and carbonic acid-bicarbonate buffers in the corrosion processes of the oral cavityDental Materials, 1985
- Effect of zinc in two non-gamma-2 dental amalgam systemsDental Materials, 1985
- Change in the Hardness of Dental Amalgams in relation to TimeDental Materials Journal, 1983
- Electrochemical behavior of Sn8Hg (gamma-2) and dental amalgam in a phosphate buffer solutionElectrochimica Acta, 1980
- Creep, corrosion and marginal fracture of dental amalgamsJournal of Oral Rehabilitation, 1978
- Revised American Dental Association Specification No. 1 for Alloy for Dental AmalgamThe Journal of the American Dental Association, 1977
- Marginal Failure of Amalgam Class II RestorationJournal of Dental Research, 1977
- In vitro corrosion of dental amalgam phasesJournal of Biomedical Materials Research, 1976