Evaluation of the image quality of ink-jet printed paper copies of digital chest radiographs as compared with film: A receiver operating characteristic study
Authors:
- 1 May 1994
- journal article
- research article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 7 (2) , 61-68
Abstract
Paper copies of digital radiographs printed with the continuous ink-jet technique have proved to be of a high enough quality for demonstration purposes. We present a study on the image quality of ink-jet printed paper copies of digital chest radiographs, based on receiver operating characteristic (ROC) analysis. Eighty-three digital radiographs of a chest phatom with simulated tumors in the mediastinum and right lund, derived from a computed radiography (CR) system were presented in two series of hard copies as ink-jet printed paper copies and as laser recorded film. The images, with a matrix of 1,760×2,140 pixels, were printed with a spatial resolution of 10 pixels/mm in the CR film recorder as well as in the ink-jet printer. On film, every image was recorded in two versions, one optimized for the mediastinum and one for the lungs. On paper, only one image was printed; this constituted an effort to optimize both the mediastinum and the lungs. The ink-jet printed images, printed on a matt coated paper, were viewed as on-sight images with reflected light. The exdaminations were reviewed by six radiologists, and ROC curves were constructed. No significant difference was found between the performance of film and that of ink-jet paper prints. Because the cost for a paper copy is only a tenth of that of film, remarkable cost reductions can be achieved by using the ink jet technique instead. Our results show that further quality studies of ink-jet printed images are worthwhile.Keywords
This publication has 8 references indexed in Scilit:
- Digital luminescence radiography using a chest phantom. Comparison between radiographs displayed on monitor at a workstation and at a personal.1993
- Digital Luminescence Radiography Using a Chest PhantomActa Radiologica, 1993
- Demonstration of digital radiographs by means of ink jet-printed paper copies: Pilot studyJournal of Digital Imaging, 1992
- The use of ink jets in ultrasound registrationsUltrasound in Medicine & Biology, 1991
- Ink jet color printing of digital medical images.1990
- Ink Jet Color Printing of Digital Medical ImagesActa Radiologica, 1990
- Some Practical Issues of Experimental Design and Data Analysis in Radiological ROC StudiesInvestigative Radiology, 1989
- ROC Methodology in Radiologic ImagingInvestigative Radiology, 1986