A compact miniaturized continuous flow system for the determination of urea content in milk
- 9 August 2010
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 398 (3) , 1525-1533
Abstract
A multicommutation-based flow system with photometric detection was developed, employing an analytical microsystem constructed with low temperature co-fired ceramics (LTCC) technology, a solid-phase reactor containing particles of Canavalia ensiformis DC (urease source) immobilized with glutaraldehyde, and a mini-photometer coupled directly to the microsystem which monolithically integrates a continuous flow cell. The determination of urea in milk was based on the hydrolysis of urea in the solid-phase reactor and the ammonium ions produced were monitored using the Berthelot reaction. The analytical curve was linear in the urea concentration range from 1.0 × 10−4 to 5.0 × 10−3 mol L−1 with a limit of detection of 8.0 × 10−6 mol L−1. The relative standard deviation (RSD) for a 2.0 × 10−3 mol L−1 urea solution was lower than 0.4% (n = 10) and the sample throughput was 13 h−1. To check the reproducibility of the flow system, calibration curves were obtained with freshly prepared solutions on different days and the RSD obtained was 4.7% (n = 6). Accuracy was assessed by comparing the results of the proposed method with those from the official procedure and the data are in close agreement, at a 95% confidence level.Keywords
This publication has 22 references indexed in Scilit:
- Ceramic Microsystem Incorporating a Microreactor with Immobilized Biocatalyst for Enzymatic Spectrophotometric AssaysAnalytical Chemistry, 2009
- A Monolithic Continuous-Flow Microanalyzer with Amperometric Detection Based on the Green Tape TechnologyAnalytical Chemistry, 2009
- Potentiometric biosensor for urea determination in milkSensors and Actuators B: Chemical, 2009
- LTCC meso-analytical system for chloride ion determination in drinking watersSensors and Actuators B: Chemical, 2006
- Continuous Flow Analytical Microsystems Based on Low-Temperature Co-Fired Ceramic Technology. Integrated Potentiometric Detection Based on Solvent Polymeric Ion-Selective ElectrodesAnalytical Chemistry, 2006
- Relationships Between Milk Urea and Production, Nutrition, and Fertility Traits in Israeli Dairy HerdsJournal of Dairy Science, 2004
- Overview of low temperature co-fired ceramics tape technology for meso-system technology (MsST)Sensors and Actuators A: Physical, 2001
- Sistema em fluxo para determinação espectrofotométrica de uréia em plasma de sangue animal empregando leguminosa como fonte natural da enzima ureaseQuímica Nova, 2001
- Diurnal Variation of Rumen Ammonia, Serum Urea, and Milk Urea in Dairy Cows at High and Low YieldsJournal of Dairy Science, 1993
- Utilization of Urea by Lactating Cows — an Industry ViewpointJournal of Animal Science, 1975