Simulation of Portal Hemodynamic Changes in a Donor After Right Hepatectomy
- 8 March 2010
- journal article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 132 (4) , 041002
Abstract
Remnant livers will be regenerated in live donors after a large volume resection for transplantation. How the structures and hemodynamics of portal vein will evolve with liver regeneration remains unknown. This prompts the present hemodynamic simulation for a 25 year-old man who received a right donor lobectomy. According to the magnetic resonance imaging/computed tomography images taken prior to the operation and one month after the operation, three sequential models of portal veins (pre-op, immediately after the operation, and one-month post-op) were constructed by AMIRA® and HYPERMESH®, while the immediately after the operation model was generated by removing the right branch in the pre-op model. Hemodynamic equations were solved subject to the sonographically measured inlet velocity. The simulated branch velocities were compared with the measured ones. The predicted overall pressure in the portal vein after resection was found to increase to a magnitude that has not reached to an extent possibly leading to portal hypertension. As expected, blood pressure has a large change only in the vicinity of the resection region. The branches grew considerably different from the original one as the liver is regenerated. Results provide useful evidence to justify the current computer simulation.Keywords
This publication has 23 references indexed in Scilit:
- Protein C inhibitor regulates hepatocyte growth factor activator-mediated liver regeneration in miceGut, 2008
- The EGF receptor is required for efficient liver regenerationProceedings of the National Academy of Sciences, 2007
- A prospective analysis of living-liver donation shows a high rate of adverse eventsJournal of Hepato-Biliary-Pancreatic Surgery, 2006
- Numerical investigation of non-Newtonian microcirculatory blood flow in hepatic lobuleJournal of Biomechanics, 2006
- Impact of Portal Venous Pressure on Regeneration and Graft Damage After Living-Donor Liver TransplantationLiver Transplantation, 2004
- Intraoperative hemodynamics and liver function in adult-to-adult living liver donorsLiver Transplantation, 2002
- Venous hemodynamics in living donor right lobe liver transplantationLiver Transplantation, 2002
- The influence of the non-Newtonian properties of blood on the flow in large arteries: unsteady flow in a 90° curved tubeJournal of Biomechanics, 1999
- Functional Analysis of Grafts from Living DonorsAnnals of Surgery, 1996
- EVIDENCE THAT PORTAL VEIN DECOMPRESSION IMPROVES SURVIVAL OF CANINE QUARTER ORTHOTOPIC LIVER TRANSPLANTATIONTransplantation, 1995