Evaluation of left ventricular mass measured by 3D echocardiography using magnetic resonance imaging as gold standard
Authors:
- J. KjaergaardJKJ. Kjaergaard
- C. L. PetersenCPC. L. Petersen
- A. KjaerA. Kjaer
- C. HassagerC. Hassager
- 1 January 2006
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 66 (8) , 647-658
Abstract
Increased left ventricular mass (LVM) and presence of left ventricular hypertrophy (LVH) are predictors of cardiovascular morbidity and mortality, but can be reversed with proper treatment of the underlying cause. Therefore accurate as well as reproducible methods for diagnosis and follow-up are needed. We evaluated different modalities by which to measure LVM in patients with no known LVH using magnetic resonance imaging (MRI) as the gold standard: ECG using the formulae proposed by Sokolow-Lyon and Cornell, 2D echocardiography and 3D echocardiography. 34 subjects were included in the study; 17 had a history of myocardial infarction, 7 had pulmonary hypertension and 10 were healthy. All patients and controls had a standard 12-lead ECG, a transthoracic 2D and 3D echocardiographic study and a cardiac MRI. ECG estimates of LVM correlated poorly with LVM by MRI (r = 0.18, NS and 0.16, NS for Sokolow-Lyon and Cornell, respectively), whereas a moderate correlation between 2D and 3D echocardiography and MRI was observed (r = 0.63, p<0.001 and r = 0.74, p<0.001, respectively). All methods were reproducible with no significant bias. LVM measured by 3D echocardiography is highly accurate compared to LVM measured by MRI. LVM calculated from 2D echocardiography also proved useful, whereas estimates of LVM by ECG are inaccurate in a non-hypertrophic population.Keywords
This publication has 21 references indexed in Scilit:
- The Accuracy of Left Ventricular Mass Determined by Real-time Three-dimensional Echocardiography in Chronic Animal and Clinical Studies: A Comparison with Postmortem Examination and Magnetic Resonance ImagingJournal of the American Society of Echocardiography, 2005
- Fast Measurement of Left Ventricular Mass With Real-Time Three-Dimensional EchocardiographyCirculation, 2004
- New Gender-Specific Partition Values for ECG Criteria of Left Ventricular HypertrophyHypertension, 2004
- Regression of Electrocardiographic Left Ventricular Hypertrophy by Losartan Versus AtenololCirculation, 2003
- Applying the right statistics: analyses of measurement studiesUltrasound in Obstetrics & Gynecology, 2003
- Echocardiographic assessment of left ventricular hypertrophy: Comparison to necropsy findingsThe American Journal of Cardiology, 1986
- Electrocardiographic detection of left ventricular hypertrophy: Development and prospective validation of improved criteriaJACC, 1985
- Canine left ventricular mass estimation by two-dimensional echocardiography.Circulation, 1983
- A Critical Appraisal of the Electrocardiographic Criteria for the Diagnosis of Left Ventricular HypertrophyCirculation, 1969
- The ventricular complex in left ventricular hypertrophy as obtained by unipolar precordial and limb leadsAmerican Heart Journal, 1949