Experiments on Integral and Local Crystallisation Fouling Resistances in a Double Pipe Heat Exchanger with Wire Matrix Inserts
- 30 July 2015
- journal article
- research article
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 37 (1) , 24-31
Abstract
Wire matrix inserts are used in different applications of tubular heat exchangers to improve tube side heat transfer. They have also been used to suppress fouling in crude oil refining services. In this paper it is investigated whether the changed hydrodynamic and thermal conditions when applying wire matrix inserts have an impact on crystallization fouling compared to the plain tube. With a turbulent flow, at Reynolds number of 9877 and an inlet temperature of 42°C, fouling tests with an aqueous calcium sulfate solution for two wire matrix inserts with a different packing density were carried out and compared with a plain tube. Integral and local measurements of the fouling were performed. The experiments were realized in a double-pipe heat exchanger with a pipe length of 2000 mm. The integral fouling resistances between the inserts and the plain tube showed no significant difference, whereas major differences of the local fouling resistances were observed. Compared to the plain tube, the inserts showed an increased heat transfer up to a maximum of 35% but also a significantly increased pressure drop. Fouling on the inserts themselves, which was observed optically, is the possible explanation for this behavior.Keywords
This publication has 10 references indexed in Scilit:
- Crystallization Fouling in Experimental Micro Heat Exchangers—Optical and Thermal InvestigationsExperimental Heat Transfer, 2013
- Fouling thresholds in bare tubes and tubes fitted with insertsApplied Energy, 2012
- Roughness and constriction effects on heat transfer in crystallization foulingChemical Engineering Science, 2011
- Determination of Heat Transfer Coefficients Using the Wilson‐Plot MethodChemie Ingenieur Technik, 2011
- hiTRAN® Wire Matrix Inserts in Fouling ApplicationsHeat Transfer Engineering, 2009
- Extending the Induction Period of Crystallization Fouling Through Surface CoatingHeat Transfer Engineering, 2009
- A general review of the Wilson plot method and its modifications to determine convection coefficients in heat exchange devicesApplied Thermal Engineering, 2007
- Early Events in the Precipitation Fouling of Calcium Sulphate Dihydrate under Sensible Heating ConditionsThe Canadian Journal of Chemical Engineering, 2007
- Mechanisms by Which Fouling Can Increase Overall Heat Transfer CoefficientsHeat Transfer Engineering, 1992
- Fouling of heat transfer surfacesChemical Engineering & Technology, 1987