In order to investigate the static and fatigue strength of high tensile strength steel tubular joints for offshore structures, 11 full-scale models of the joints taken from an actual in-service structure were tested under monotonic or cyclic loadings. Specimens consisted of eight welded and three cast tubular N-joints with a chord of either 760 mm or 660 mm in OD. Some of them, including three cast joints, were reinforced by thickening the portions of the chord walls where the braces were welded. The materials used for both a chord and braces of each specimen were of a JIS-HT80 (equivalent to ASTM A514 Grade F) steel with the specified ultimate tensile strength of OU ?80 kg/mm2. Characteristics of the test results were:Although the high strength steel tubular N-joints showed a less ductile failure mode compared with small-sized joints in mild steels, the ultimate static strength could be predicted by a calculation method based on punching shear stresses in the chord walls.Conventional S-N curves such as the AWS curve X were applicable for prediction of fatigue lives of tubular joints in high-strength steels.Partial thickening of the chord walls was found to be fully effective in improving the static and fatigue strengths of joints.By adopting a cast joint instead of a welded one, a fatigue life to failure of the joint was increased by about three times. INTRODUCTION: Tubular members are utilized in offshore structures such as drilling and production towers because of their advantageous cross-sectional shapes under severe environmental conditions induced by waves and current forces. The configuration of tubular joints, however, is so complicated that stresses concentrate at intersections of members and the static and fatigue strengths of the joints become too low. Appropriate reinforcements to the joints, therefore, are inevitable to secure a sufficient strength of the structure. Instead of mild steel, high-strength steel recently has been employed for the members to reduce the total weight of the structure to be installed in deeper sea areas. But it is not assured that the existing formulas for the strength of mild-steel joints are applicable to the high-strength steel joints. Therefore, the static and fatigue tests were performed with 11 full-scale N-joints in high strength steels. The objectives of the experiments are:to investigate the static and fatigue behaviors of full-scale high-strength steel joints,to check the applicability of the conventional formulas to the strength of high-strength steel joints,to develop an effective reinforcement method for the joints. TEST PROGRAM AND PROCEDURES: Specimens: Configurations and dimensions of the specimens are shown in Fig. 1 and Table 1. All the specimens are tubular N-joints with a chord of either 760 mm or 660 mm OD. The angle between the diagonal brace and the chord is 45°.