This study gives an overview of how the morphology of droplets forming in condensing conditions changes with varying levels of voltage and undercooling temperatures. Additionally, this droplet initiation and growth was investigated when the samples are placed in varying orientations (vertical, angled and horizontal) to understand the droplet dynamics causing failures. An in-house box setup was used to simulate condensation where the test PCB was placed on a heat exchanger, by cooling the samples below dew point. These tests were performed on copper-based test PCBs while placing the boxes in a climatic chamber (to maintain constant condition) under applied bias varying from 10 - 1500 V. Local corrosion cell formation due to water droplet coalescence was tracked and quantified using image analysis from in-situ images. The critical mass of droplet was calculated when the samples were placed vertically and at an angle. Furthermore, the amount of copper dissolved was quantified using ICP-OES while SEM-EDS and XPS were used to understand the corrosion product morphology and composition formed with varying orientations.