Impact of Three‐Dimensional Imaging and Pressure Recovery on Echocardiographic Evaluation of Severe Aortic Stenosis: A Pilot Study
- 22 January 2014
- journal article
- research article
- Published by Wiley in Echocardiography
- Vol. 31 (8) , 1006-1016
Abstract
Aims: In patients with aortic stenosis (AS), echocardiographic grading of stenosis severity is important, in particular for transcatheter aortic valve implantation (TAVI). Three‐dimensional (3D) echocardiography and correction for pressure recovery (PR) by energy loss index (ELI) may improve aortic valve area (AVA) calculation.Methods and Results: Thirty‐nine patients with severe AS evaluated for TAVI were included. Left ventricular outflow tract (LVOT) and ascending aorta (AA) cross‐sectional area were determined in transthoracic two‐dimensional echocardiography (2DTTE), 2D transesophageal echocardiography (TEE), 3DTEE, and multislice computed tomography (MSCT). AVA was calculated by the continuity equation and corrected for PR. ELI was determined as [(AVA × AA)/(AA − AVA)]/body surface area. LVOT area was 2.41 ± 0.17 cm2 calculated using 2DTTE, 2.82 ± 0.16 cm2 calculated using 2DTEE, 3.96 ± 0.14 cm2 planimetered in 3DTEE, and 4.47 ± 0.18 cm2 planimetered in MSCT (P < 0.001). AA area was 4.62 ± 0.23 cm2 calculated using 2DTTE, 4.64 ± 0.23 cm2 calculated using 2DTEE, 5.35 ± 0.25 cm2 planimetered in 3DTEE, and 6.56 ± 0.31 cm2 planimetered in MSCT (P < 0.001). Indexed aortic valve area (AVAI) calculated by 2DTTE and 2DTEE was smaller (0.27 ± 0.02 cm2/m2 and 0.32 ± 0.02 cm2/m2) compared to 3DTEE (0.45 ± 0.02 cm2/m2; P < 0.001). When AVAI determined by 3DTEE was corrected for PR by calculation of ELI, there was a further increase (0.52 ± 0.03 cm2/m2; P < 0.001), and 10/36 (27.8%) patients were reclassified to moderate AS.Conclusion: Three‐dimensional TEE is more accurate than 2DTTE and 2DTEE for determining LVOT and AA dimensions. When AS severity is determined by 3DTEE and corrected for PR using the 3D values, it needs to be reclassified from severe to moderate in almost a third of patients.Keywords
This publication has 34 references indexed in Scilit:
- Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve ReplacementNew England Journal of Medicine, 2012
- Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantationHeart, 2011
- Measurement of Aortic Valve Annulus Using Different Cardiac Imaging Techniques in Transcatheter Aortic Valve Implantation: Agreement with Finally Implanted Prosthesis SizeEchocardiography, 2011
- Comparison of Aortic Root Dimensions and Geometries Before and After Transcatheter Aortic Valve Implantation by 2- and 3-Dimensional Transesophageal Echocardiography and Multislice Computed TomographyCirculation: Cardiovascular Imaging, 2010
- Echocardiographic Assessment of Valve Stenosis: EAE/ASE Recommendations for Clinical PracticeJournal of the American Society of Echocardiography, 2009
- Energy loss for evaluating heart valve performanceThe Journal of Thoracic and Cardiovascular Surgery, 2008
- Demonstration of Left Ventricular Outflow Tract Eccentricity by Real Time 3D Echocardiography: Implications for the Determination of Aortic Valve AreaEchocardiography, 2007
- Analytical modeling of the instantaneous maximal transvalvular pressure gradient in aortic stenosisJournal of Biomechanics, 2006
- Differences in Tachyarrhythmia Detection and Implantable Cardioverter Defibrillator Therapy by Primary or Secondary Prevention Indication in Cardiac Resynchronization Therapy PatientsJournal of Cardiovascular Electrophysiology, 2004
- Extent, determinants and clinical importance of pressure recovery in patients with aortic valve stenosisEuropean Heart Journal, 1999