Evaluation of 19-gauge endoscopic ultrasonography aspiration needles using various echoendoscopes
Authors:
Open Access
- 19 December 2013
- journal article
- research article
- Published by Georg Thieme Verlag KG in Endoscopy International Open
- Vol. 1 (01) , 24-30
Abstract
Background and study aims: 19-gauge (19G) needles are used for EUS-guided tissue acquisition and interventions. The aim of the current study was to compare the functional characteristics of 19G EUS needles by means of using various echoendoscopes in a bench simulator. Methods: The angles achieved for 19G needles (EchoTip: ET-19G, EchoTip Flex: ExF-19G, Expect: Ex-19G, and ProCore: PC-19G) and for the distal tip of the echoendoscope were evaluated for maximal angulation settings of the distal tip and the elevator. Also the resistance to advancement of the 19G needles at these endoscope settings was assessed. All evaluations were done with endoscopes in a straight and in a curved position. Results: There was no large discrepancy for scope and needle angles among all echoendoscopes except for the slim Pentax scope (EG-3270UK). The ExF-19G and PC-19G needles showed better optimal angles in various conditions compared to standard 19G needles. In straight scope position, out of the 20 conditions (5 endoscopes × 2 positions of the distal tip × 2 elevator positions) the numbers of optimal angulations achieved for the Ex-19G, ExF-19G, ET-19G, and PC-19G, were 11 /20 (55 %), 20 /20 (100 %), 14 /20 (70 %) and 18 /20 (90 %), respectively. However, regarding resistance, it was impossible to advance theneedle with 14 /20 settings (70 %) for the Ex-19G, 3 /20 (15 %) for the ExF-19G, 10 /20 (50 %) for the ET-19G and 7 /20 (35 %) for the PC-19G. When the scopes were bent, with regard to the force needed to advance the needle, the numbers of optimal settings, for the Ex-19G, ExF-19G, ET-19G, and PC-19G, were 1 (5 %), 13 (65 %), 6 (30 %) and 8 (40 %), respectively. The mean maximum resistance to advancement was less for the ExF-19G than for the other needless in almost all scope and angle conditions (p < 0.05). Conclusion: Although there was no difference between needles, the resistance to passage was least with the flexible 19-gauge needle (ExF-19G).Keywords
This publication has 23 references indexed in Scilit:
- Use of Samples From Endoscopic Ultrasound–Guided 19-Gauge Fine-Needle Aspiration in Diagnosis of Autoimmune PancreatitisClinical Gastroenterology and Hepatology, 2012
- Prospective Clinical Study of EUS-Guided Choledochoduodenostomy for Malignant Lower Biliary Tract ObstructionAmerican Journal of Gastroenterology, 2011
- Stent selection and tips on placement technique of EUS‐guided biliary drainage: transduodenal and transgastric stentingJournal of Hepato-Biliary-Pancreatic Sciences, 2011
- EUS-guided rendezvous with single-balloon enteroscopy for treatment of stenotic pancreaticojejunal anastomosis in post-Whipple patients (with video)Gastrointestinal Endoscopy, 2011
- Endoscopic ultrasonography‐guided gallbladder drainage: actual technical presentations and review of the literature (with videos)Journal of Hepato-Biliary-Pancreatic Sciences, 2010
- ENDOSONOGRAPHY‐GUIDED BILIARY DRAINAGE IN CASES WITH DIFFICULT TRANSPAPILLARY ENDOSCOPIC BILIARY DRAINAGEDigestive Endoscopy, 2009
- Prospective comparative study of the EUS guided 25‐gauge FNA needle with the 19‐gauge Trucut needle and 22‐gauge FNA needle in patients with solid pancreatic massesJournal of Gastroenterology and Hepatology, 2009
- Experimental endoscopy: objective evaluation of EUS needlesGastrointestinal Endoscopy, 2009
- EUS versus surgical cyst-gastrostomy for management of pancreatic pseudocystsGastrointestinal Endoscopy, 2008
- Hepaticogastrostomy by Echo-Endoscopy as a Palliative Treatment in a Patient with Metastatic Biliary ObstructionEndoscopy, 2003