Image quality improvement in low‐dose chest CT with deep learning image reconstruction
Authors:
Open Access
- 9 October 2022
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 23 (12) , e13796
Abstract
Objectives: To investigate the clinical utility of deep learning image reconstruction (DLIR) for improving image quality in low‐dose chest CT in comparison with 40% adaptive statistical iterative reconstruction‐Veo (ASiR‐V40%) algorithm.Methods: This retrospective study included 86 patients who underwent low‐dose CT for lung cancer screening. Images were reconstructed with ASiR‐V40% and DLIR at low (DLIR‐L), medium (DLIR‐M), and high (DLIR‐H) levels. CT value and standard deviation of lung tissue, erector spinae muscles, aorta, and fat were measured and compared across the four reconstructions. Subjective image quality was evaluated by two blind readers from three aspects: image noise, artifact, and visualization of small structures.Results: The effective dose was 1.03 ± 0.36 mSv. There was no significant difference in CT values of erector spinae muscles and aorta, whereas the maximum difference for lung tissue and fat was less than 5 HU among the four reconstructions. Compared with ASiR‐V40%, the DLIR‐L, DLIR‐M, and DLIR‐H reconstructions reduced the noise in aorta by 11.44%, 33.03%, and 56.1%, respectively, and had significantly higher subjective quality scores in image artifacts (all p < 0.001). ASiR‐V40%, DLIR‐L, and DLIR‐M had equivalent score in visualizing small structures (all p > 0.05), whereas DLIR‐H had slightly lower score.Conclusions: Compared with ASiR‐V40%, DLIR significantly reduces image noise in low‐dose chest CT. DLIR strength is important and should be adjusted for different diagnostic needs in clinical application.Keywords
This publication has 19 references indexed in Scilit:
- Deep learning–based image restoration algorithm for coronary CT angiographyEuropean Radiology, 2019
- Detection of Colorectal Hepatic Metastases Is Superior at Standard Radiation Dose CT versus Reduced Dose CTRadiology, 2019
- Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed TomographyJACC: Cardiovascular Imaging, 2018
- Third version of vendor-specific model-based iterativereconstruction (Veo 3.0): evaluation of CT image quality in the abdomen using new noise reduction presets and varied slice optimizationBritish Journal of Radiology, 2017
- Head-to-head comparison of adaptive statistical and model-based iterative reconstruction algorithms for submillisievert coronary CT angiographyEuropean Heart Journal - Cardiovascular Imaging, 2017
- Evaluation of Abdominal Computed Tomography Image Quality Using a New Version of Vendor-Specific Model-Based Iterative ReconstructionJournal of Computer Assisted Tomography, 2017
- What is the preferred strength setting of the sinogram-affirmed iterative reconstruction algorithm in abdominal CT imaging?Radiological Physics and Technology, 2014
- Screening for Lung Cancer: U.S. Preventive Services Task Force Recommendation StatementAnnals of Internal Medicine, 2014
- Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic ScreeningNew England Journal of Medicine, 2011
- Iterative image reconstruction techniques: Applications for cardiac CTJournal of Cardiovascular Computed Tomography, 2011