Ultra-Low-Dose CT of the Thorax Using Iterative Reconstruction: Evaluation of Image Quality and Radiation Dose Reduction
Authors:
- 1 June 2015
- journal article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 204 (6) , 1197-1202
Abstract
The purpose of this study is to assess the image quality and radiation dose reduction of ultra-low-dose CT using sinogram-affirmed iterative reconstruction (SAFIRE). This prospective study enrolled 25 patients who underwent three consecutive unenhanced CT scans including low-dose CT (120 kVp and 30 mAs) and two ultra-low-dose CT protocols (protocol A, 100 kVp and 20 mAs; protocol B, 80 kVp and 30 mAs) with image reconstruction using SAFIRE. The image quality and radiation dose reduction were assessed. The mean (± SD) effective radiation dose was 1.06 ± 0.11, 0.44 ± 0.05, and 0.31 ± 0.03 mSv for low-dose CT, ultra-low-dose CT protocol A, and ultra-low-dose CT protocol B, respectively. Overall image quality was determined as diagnostic in 100% of low-dose CT scans, 96% of ultra-low-dose CT protocol A scans, and 88% of ultra-low-dose CT protocol B scans. All patients with nondiagnostic quality images had a body mass index (weight in kilograms divided by the square of height in meters) greater than 25. There was no statistically significant difference in detection frequencies of 14 lesion types among the three CT protocols, but pulmonary emphysema was detected in fewer patients (3/25) in ultra-low-dose CT protocol B scans compared with ultra-low-dose CT protocol A scans (5/25) or low-dose CT scans (6/25). We measured the longest dimensions of 33 small solid nodules (3.8-12.4 mm in long diameter) and found no statistically significant difference in the values afforded by the three CT protocols (p = 0.135). Iterative reconstruction allows ultra-low-dose CT and affords acceptable image quality, allowing size measurements of solid pulmonary nodules to be made.Keywords
This publication has 20 references indexed in Scilit:
- Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstructionEuropean Radiology, 2014
- Impact of the adaptive statistical iterative reconstruction technique on image quality in ultra-low-dose CTClinical Radiology, 2013
- Accuracy of low-dose computed tomography (CT) for detecting and characterizing the most common CT-patterns of pulmonary diseaseEuropean Journal of Radiology, 2013
- Iterative reconstruction techniques for computed tomography part 2: initial results in dose reduction and image qualityEuropean Radiology, 2013
- Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observationsEuropean Radiology, 2012
- Low-dose CT of the lung: potential value of iterative reconstructionsEuropean Radiology, 2012
- Radiation Dose Reduction of Chest CT with Iterative Reconstruction in Image Space - Part I: Studies on Image Quality Using Dual Source CTKorean Journal of Radiology, 2012
- Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique—comparison with traditional filtered back projectionEuropean Radiology, 2011
- Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patientsEuropean Radiology, 2010
- Radiation Dose Reduction in Chest CT: A ReviewAmerican Journal of Roentgenology, 2008