Serial High Resolution CT Findings in Nonspecific Interstitial Pneumonia/Fibrosis

Authors:
  • YKYasuhiro Kondoh
    Yasuhiro Kondoh
  • HTHiroyuki Taniguchi
    Hiroyuki Taniguchi
  • KYKenichi Yamaki
    Kenichi Yamaki
  • RSRyujiro Suzuki
    Ryujiro Suzuki
  • TYToyoharu Yokoi
    Toyoharu Yokoi
  • KTKenzo Takagi
    Kenzo Takagi

Abstract
The purpose of this work was to evaluate the radiographic and serial high resolution CT (HRCT) findings in patients with nonspecific interstitial pneumonia/fibrosis (NSIP). We identified 15 patients with biopsy-proven NSIP. Radiography and initial and follow-up CT findings were reviewed. Predominant radiographic findings were bilateral infiltrates distributing in the middle and lower lung zones and decreased lung volumes. At initial CT, predominant patterns were peribronchovascular interstitial thickening (n = 6), parenchymal bands (n = 8), intralobular interstitial thickening (n = 12), and traction bronchiectasis (n = 14). Mixed pattern of ground-glass opacity and consolidation (n = 11) were predominant findings of increased lung opacity. At follow-up CT in 14 cases, the abnormalities had disappeared completely in 3, improved in 9, persisted in 1, and worsened in 1. The pulmonary abnormalities observed in NSIP on HRCT can disappear or be diminished in most cases after corticosteroid therapy. Intralobular interstitial thickening and traction bronchiectasis, which have been considered to be indicators of irreversible fibrosis, also show favorable responses.

This publication has 24 references indexed in Scilit: