Staff Radiation Doses in Interventional Cardiology: Correlation With Patient Exposure
- 29 January 2009
- journal article
- research article
- Published by Springer Nature in Pediatric Cardiology
- Vol. 30 (4) , 409-413
Abstract
In pediatric interventional cardiology, cardiologists need to stay closer to the patient than during adult catheterization, and the use of biplane systems increases the scatter radiation. Occupational radiation risk is rather high, and estimation of lens doses becomes necessary. Deriving factors for assessing these doses from the patient doses displayed in catheterization laboratories can help in preserving staff radiation safety. A biplane X-ray system and polymethylmethacrylate plates of 4 to 20 cm to simulate pediatric patients have been used. Patient entrance dose rates, dose-area product, and doses to the eyes of the cardiologists for the typical operation modes have been measured. Correlations between patient and staff doses have been obtained. Scatter dose rates increase by a factor of 92 from low fluoroscopy to cine acquisition when phantom thickness increases from 4 to 20 cm. Scatter doses increase linearly with dose-area product for all the thicknesses. Administration of 1 Gy·cm2 to the patient involves 7 μSv to the eyes of the cardiologist (without extra protection). In conclusion, the experimental correlation factors found between phantom and scatter doses allow a fairly good estimation of staff doses from the dosimetric patient data.Keywords
This publication has 19 references indexed in Scilit:
- Eye Lens Exposure to Radiation in Interventional Suites: Caution Is WarrantedRadiology, 2008
- Radiation exposure in invasive cardiologyHeart, 2008
- OCCUPATIONAL RADIATION DOSES TO OPERATORS PERFORMING CARDIAC CATHETERIZATION PROCEDURESHealth Physics, 2008
- Preface, Executive Summary and GlossaryAnnals of the ICRP, 2007
- Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiologyRadiation Protection Dosimetry, 2006
- Monte Carlo calculations for assessment of radiation dose to patients with congenital heart defects and to staff during cardiac catheterizationsBritish Journal of Radiology, 2003
- Effective doses to patients from paediatric cardiac catheterization.British Journal of Radiology, 2000
- Radiation exposure to medical staff in interventional and cardiac radiology.British Journal of Radiology, 1998
- Occupational Exposure in Pediatric Cardiac CatheterizationHealth Physics, 1995
- Radiation exposure of pediatric patients and physicians during cardiac catheterization and balloon pulmonary valvuloplastyThe American Journal of Cardiology, 1991