Noninvasive Estimation of Global Activation Sequence Using the Extended Kalman Filter
- 16 August 2010
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (3) , 541-549
Abstract
A new algorithm for 3-D imaging of the activation sequence from noninvasive body surface potentials is proposed. After formulating the nonlinear relationship between the 3-D activation sequence and the body surface recordings during activation, the extended Kalman filter (EKF) is utilized to estimate the activation sequence in a recursive way. The state vector containing the activation sequence is optimized during iteration by updating the error variance/covariance matrix. A new regularization scheme is incorporated into the “predict” procedure of EKF to tackle the ill-posedness of the inverse problem. The EKF-based algorithm shows good performance in simulation under single-site pacing. Between the estimated activation sequences and true values, the average correlation coefficient (CC) is 0.95, and the relative error (RE) is 0.13. The average localization error (LE) when localizing the pacing site is 3.0 mm. Good results are also obtained under dual-site pacing (CC = 0.93, RE = 0.16, and LE = 4.3 mm). Furthermore, the algorithm shows robustness to noise. The present promising results demonstrate that the proposed EKF-based inverse approach can noninvasively estimate the 3-D activation sequence with good accuracy and the new algorithm shows good features due to the application of EKF.Keywords
This publication has 29 references indexed in Scilit:
- Non-Invasive Imaging of Cardiac Activation and RecoveryAnnals of Biomedical Engineering, 2009
- Estimation of Global Ventricular Activation Sequences by Noninvasive Three‐Dimensional Electrical Imaging: Validation Studies in a Swine Model During PacingJournal of Cardiovascular Electrophysiology, 2008
- Single-Beat Noninvasive Imaging of Cardiac Electrophysiology of Ventricular Pre-ExcitationJACC, 2006
- Electrocardiographic imaging of cardiac resynchronization therapy in heart failure: Observation of variable electrophysiologic responsesHeart Rhythm, 2006
- Noninvasive three-dimensional electrocardiographic imaging of ventricular activation sequenceAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- An analytical comparison of three spatio-temporal regularization methods for dynamic linear inverse problems in a common statistical frameworkInverse Problems, 2005
- Solving the Inverse Problem of Electrocardiography Using a Duncan and Horn Formulation of the Kalman FilterIEEE Transactions on Biomedical Engineering, 2004
- The temporal prior in bioelectromagnetic source imaging problemsIEEE Transactions on Biomedical Engineering, 2003
- Localization of the site of origin of cardiac activation by means of a heart-model-based electrocardiographic imaging approachIEEE Transactions on Biomedical Engineering, 2001
- The use of temporal information in the regularization of the inverse problem of electrocardiographyIEEE Transactions on Biomedical Engineering, 1992