The effects of positive end-expiratory pressure on cardiac function: a comparative echocardiography-conductance catheter study
Authors:
Open Access
- 6 April 2022
- journal article
- research article
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 111 (6) , 705-719
Abstract
Background: Echocardiographic parameters of diastolic function depend on cardiac loading conditions, which are altered by positive pressure ventilation. The direct effects of positive end-expiratory pressure (PEEP) on cardiac diastolic function are unknown. Methods: Twenty-five patients without apparent diastolic dysfunction undergoing coronary angiography were ventilated noninvasively at PEEPs of 0, 5, and 10 cmH2O (in randomized order). Echocardiographic diastolic assessment and pressure–volume-loop analysis from conductance catheters were compared. The time constant for pressure decay (τ) was modeled with exponential decay. End-diastolic and end-systolic pressure volume relationships (EDPVRs and ESPVRs, respectively) from temporary caval occlusion were analyzed with generalized linear mixed-effects and linear mixed models. Transmural pressures were calculated using esophageal balloons. Results: τ values for intracavitary cardiac pressure increased with the PEEP (n = 25; no PEEP, 44 ± 5 ms; 5 cmH2O PEEP, 46 ± 6 ms; 10 cmH2O PEEP, 45 ± 6 ms; p < 0.001). This increase disappeared when corrected for transmural pressure and diastole length. The transmural EDPVR was unaffected by PEEP. The ESPVR increased slightly with PEEP. Echocardiographic mitral inflow parameters and tissue Doppler values decreased with PEEP [peak E wave (n = 25): no PEEP, 0.76 ± 0.13 m/s; 5 cmH2O PEEP, 0.74 ± 0.14 m/s; 10 cmH2O PEEP, 0.68 ± 0.13 m/s; p = 0.016; peak A wave (n = 24): no PEEP, 0.74 ± 0.12 m/s; 5 cmH2O PEEP, 0.7 ± 0.11 m/s; 10 cmH2O PEEP, 0.67 ± 0.15 m/s; p = 0.014; E’ septal (n = 24): no PEEP, 0.085 ± 0.016 m/s; 5 cmH2O PEEP, 0.08 ± 0.013 m/s; 10 cmH2O PEEP, 0.075 ± 0.012 m/s; p = 0.002]. Conclusions: PEEP does not affect active diastolic relaxation or passive ventricular filling properties. Dynamic echocardiographic filling parameters may reflect changing loading conditions rather than intrinsic diastolic function. PEEP may have slight positive inotropic effects. Clinical trial registration: https://clinicaltrials.gov/ct2/show/NCT02267291, registered 17. October 2014. GraphicalKeywords
Funding Information
- Gottfried und Julia Bangerter-Rhyner-Stiftung
- Schweizerische Herzstiftung
- University of Bern
This publication has 48 references indexed in Scilit:
- Echocardiographic Measures of Diastolic Function Are Preload Dependent during Triggered Positive Pressure Ventilation: A Controlled Crossover Study in Healthy SubjectsCritical Care Research and Practice, 2012
- Heart lung interactions during mechanical ventilationCurrent Opinion in Critical Care, 2012
- Transthoracic Echocardiography with Doppler Tissue Imaging predicts weaning failure from mechanical ventilation: evolution of the left ventricle relaxation rate during a spontaneous breathing trial is the key factor in weaning outcomeCritical Care, 2012
- Echocardiography: a help in the weaning processCritical Care, 2010
- Echocardiographic diagnosis of pulmonary artery occlusion pressure elevation during weaning from mechanical ventilation*Critical Care Medicine, 2009
- Diastolic dysfunctionJACC, 2004
- Lack of relationship between doppler indices of diastolic function and left ventricular pressure transients in patients with definite diastolic heart failureAmerican Heart Journal, 2004
- The thermodilution method for the clinical assessment of cardiac outputIntensive Care Medicine, 1995
- Hemodynamic determinants of the time-course of fall in canine left ventricular pressure.Journal of Clinical Investigation, 1976
- The estimation of oxygen consumptionCardiovascular Research, 1970