Correlating multidimensional fetal heart rate variability analysis with acid-base balance at birth
Authors:
- Martin G FraschMartin G Frasch
- Yawen XuYXYawen Xu
- Tamara StampalijaTSTamara Stampalija
- Lucien D DurosierLDLucien D Durosier
- Christophe HerryCHChristophe Herry
- Xiaogang WangXWXiaogang Wang
- Daniela CasatiDCDaniela Casati
- Andrew Je SeelyASAndrew Je Seely
- Zarko AlfirevicZAZarko Alfirevic
- Xin GaoXGXin Gao
- Enrico FerrazziEFEnrico Ferrazzi
- 19 November 2014
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 35 (12) , L1-L12
Abstract
Fetal monitoring during labour currently fails to accurately detect acidemia. We developed a method to assess the multidimensional properties of fetal heart rate variability (fHRV) from trans-abdominal fetal electrocardiogram (fECG) during labour. We aimed to assess this novel bioinformatics approach for correlation between fHRV and neonatal pH or base excess (BE) at birth.We enrolled a prospective pilot cohort of uncomplicated singleton pregnancies at 38-42 weeks' gestation in Milan, Italy, and Liverpool, UK. Fetal monitoring was performed by standard cardiotocography. Simultaneously, with fECG (high sampling frequency) was recorded. To ensure clinician blinding, fECG information was not displayed. Data from the last 60 min preceding onset of second-stage labour were analyzed using clinically validated continuous individualized multiorgan variability analysis (CIMVA) software in 5 min overlapping windows. CIMVA allows simultaneous calculation of 101 fHRV measures across five fHRV signal analysis domains. We validated our mathematical prediction model internally with 80:20 cross-validation split, comparing results to cord pH and BE at birth.The cohort consisted of 60 women with neonatal pH values at birth ranging from 7.44 to 6.99 and BE from -0.3 to -18.7 mmol L(-1). Our model predicted pH from 30 fHRV measures (R(2) = 0.90, P < 0.001) and BE from 21 fHRV measures (R(2) = 0.77, P < 0.001).Novel bioinformatics approach (CIMVA) applied to fHRV derived from trans-abdominal fECG during labor correlated well with acid-base balance at birth. Further refinement and validation in larger cohorts are needed. These new measurements of fHRV might offer a new opportunity to predict fetal acid-base balance at birth.Keywords
This publication has 32 references indexed in Scilit:
- Sampling rate of heart rate variability impacts the ability to detect acidemia in ovine fetuses near-termFrontiers in Pediatrics, 2014
- Continuous multivariate electronic fetal monitoring during labor detects early onset of acidemia: Prospective study in fetalsheep modelJournal of Critical Care, 2013
- Monitoring and Identification of Sepsis Development through a Composite Measure of Heart Rate VariabilityPLOS ONE, 2012
- Electronic fetal heart rate monitoring and its relationship to neonatal and infant mortality in the United StatesAmerican Journal of Obstetrics and Gynecology, 2011
- ST analysis of fetal electrocardiography in laborSeminars in Fetal and Neonatal Medicine, 2011
- Review and classification of variability analysis techniques with clinical applicationsBioMedical Engineering OnLine, 2011
- Heart Rate Variability Analysis Allows Early Asphyxia Detection in Ovine FetusReproductive Sciences, 2009
- Nonlinear properties of vagal and sympathetic modulations of heart rate variability in ovine fetus near termAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2009
- Measures of acidosis with repetitive umbilical cord occlusions leading to fetal asphyxia in the near-term ovine fetusAmerican Journal of Obstetrics and Gynecology, 2009
- Power Spectrum Analysis of Heart Rate Fluctuation: A Quantitative Probe of Beat-to-Beat Cardiovascular ControlScience, 1981