AR2, a novel automatic muscle artifact reduction software method for ictal EEG interpretation: Validation and comparison of performance with commercially available software
Open Access
- 4 April 2017
- journal article
- neuroimaging
- Published by F1000 Research Ltd in F1000Research
- Vol. 6, 30
Abstract
Objective: To develop a novel software method (AR2) for reducing muscle contamination of ictal scalp electroencephalogram (EEG), and validate this method on the basis of its performance in comparison to a commercially available software method (AR1) to accurately depict seizure-onset location. Methods: A blinded investigation used 23 EEG recordings of seizures from 8 patients. Each recording was uninterpretable with digital filtering because of muscle artifact and processed using AR1 and AR2 and reviewed by 26 EEG specialists. EEG readers assessed seizure-onset time, lateralization, and region, and specified confidence for each determination. The two methods were validated on the basis of the number of readers able to render assignments, confidence, the intra-class correlation (ICC), and agreement with other clinical findings. Results: Among the 23 seizures, two-thirds of the readers were able to delineate seizure-onset time in 10 of 23 using AR1, and 15 of 23 using AR2 (p<0.01). Fewer readers could lateralize seizure-onset (p<0.05). The confidence measures of the assignments were low (probable-unlikely), but increased using AR2 (p<0.05). The ICC for identifying the time of seizure-onset was 0.15 (95% confidence interval (CI), 0.11-0.18) using AR1 and 0.26 (95% CI 0.21-0.30) using AR2. The EEG interpretations were often consistent with behavioral, neurophysiological, and neuro-radiological findings, with left sided assignments correct in 95.9% (CI 85.7-98.9%, n=4) of cases using AR2, and 91.9% (77.0-97.5%) (n=4) of cases using AR1. Conclusions: EEG artifact reduction methods for localizing seizure-onset does not result in high rates of interpretability, reader confidence, and inter-reader agreement. However, the assignments by groups of readers are often congruent with other clinical data. Utilization of the AR2 software method may improve the validity of ictal EEG artifact reduction.Keywords
Funding Information
- Epilepsy Foundation
This publication has 26 references indexed in Scilit:
- Independent EEG Sources Are DipolarPLOS ONE, 2012
- CUDAICA: GPU Optimization of Infomax-ICA EEG AnalysisComputational Intelligence and Neuroscience, 2012
- Automated artifact removal as preprocessing refines neonatal seizure detectionClinical Neurophysiology, 2011
- ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal featuresPsychophysiology, 2011
- Identifying reliable independent components via split-half comparisonsNeuroImage, 2009
- Decreased white matter integrity in late-myelinating fiber pathways in Alzheimer's disease supports retrogenesisNeuroImage, 2009
- Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysisNeuroImage, 2007
- Independent Component Analysis Removing Artifacts in Ictal RecordingsEpilepsia, 2004
- Focal Ictal β Discharge on Scalp EEG Predicts Excellent Outcome of Frontal Lobe Epilepsy SurgeryEpilepsia, 2002
- Complex partial seizures of frontal lobe originAnnals of Neurology, 1985