Patients with mechanical circulatory support bridged to a heart transplant (HTx) are at higher risk of postoperative graft dysfunction. In this subset, a mode of graft preservation that shortens graft ischaemia should be beneficial. The outcomes of 38 patients on mechanical circulatory support (extracorporeal life support, left ventricular assist device and biventricular assist device) who received a HTx between 2015 and 2020 were analysed according to the method of graft preservation: cold storage (CS) group, 24 (63%) or ex vivo perfusion (EVP) group, 14 (37%). The median age was 57 (range 30–73) vs 64 (35–75) years (P = 0.10); 88% were men (P = 0.28); extracorporeal life support was more frequent in the CS group (54% vs 36%; P = 0.27) versus left ventricular and biventricular assist devices in the EVP group (46% vs 64%; P = 0.27). Clamping time was shorter in the EVP group (P < 0.001) and ischaemic time >4 h was higher in the CS group (P = 0.01). Thirty-day mortality was 13% (0–27%) in the CS group and 0% (P = 0.28) in the EVP group. A significantly lower primary graft failure [7% (0–23%) vs 42% (20–63%); P = 0.03] was observed in the EVP group. Survival at 1 year was 79 ± 8% (63–95%) in the CS group and 84 ± 10% (64–104%) in the EVP group (P = 0.95). Our results support the use of ex vivo graft perfusion in patients on mechanical circulatory support as a bridge to a HTx. This technique, by shortening graft ischaemic time, seems to improve post-HTx outcomes.Keywords
This publication has 25 references indexed in Scilit:
- Evaluation of the Organ Care System in Heart Transplantation With an Adverse Donor/Recipient ProfileThe Annals of Thoracic Surgery, 2014
- Comparison of Biventricular and Left Ventricular Assist Devices for the Management of Severe Right Ventricular Dysfunction in Patients with End-Stage Heart FailureASAIO Journal, 2014
- The Impact of Pretransplantation Urgency Status and the Presence of a Ventricular Assist Device on Outcome After Heart TransplantationTransplantation Proceedings, 2014
- Report from a consensus conference on primary graft dysfunction after cardiac transplantationThe Journal of Heart and Lung Transplantation, 2014
- Refractory Heart Failure Dependent on Short-Term Mechanical Circulatory Support: What Next? Heart Transplant or Long-Term Ventricular Assist DeviceArtificial Organs, 2013
- The Effect of Ventricular Assist Devices on Long-Term Post-Transplant Outcomes: A Systematic Review of Observational StudiesEuropean Journal of Heart Failure, 2011
- International Society for Heart and Lung Transplantation working formulation of a standardized nomenclature for cardiac allograft vasculopathy—2010The Journal of Heart and Lung Transplantation, 2010
- The Effect of Ventricular Assist Devices on Post-Transplant MortalityJACC, 2009
- Revision of the 1990 Working Formulation for the Standardization of Nomenclature in the Diagnosis of Heart RejectionThe Journal of Heart and Lung Transplantation, 2005
- Does successful bridging with the implantable left ventricular assist device affect cardiac transplantation outcome?The Journal of Thoracic and Cardiovascular Surgery, 1996