Abstract
Purpose: To compare results between toric implantable collamer lens (TICL) implantation and bioptics (ICL and excimer laser ablation) for the correction of myopic astigmatism. Methods: A retrospective evaluation was performed in 29 eyes (20 patients) with TICL implantation and 26 eyes (17 patients) treated with bioptics. For eyes treated with bioptics, corneal ablation was performed at 1.5 to 5 months (mean 2.56 months) after ICL implantation by laser epithelial keratomileusis in 17 eyes, LASIK in 8 eyes, and photorefractive keratectomy in 1 eye. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity, refraction, adverse events, safety, and efficacy were assessed preoperatively and 1, 6, and 12 months postoperatively. Results: At 1 month postoperatively, UDVA in the TICL group was significantly higher than in the bioptics group ( P =.02). However, the difference in UDVA at 12 months was not significant. At 12 months, mean spherical equivalent refraction was 0.33±0.21 diopters (D) in the TICL group and 0.29±0.41 D in the bioptics group ( P =.07). Mean astigmatic error was higher in the TICL group (−0.42±0.32 D) than in the bioptics group (−0.32±0.38 D) ( P =.10). In the bioptics group, the mean refractive cylinder at 12 months decreased from that reported at 6 months because of retreatment performed in two eyes. Safety and efficacy were not statistically different between groups. One eye with a TICL was treated to correct TICL decentration. Two crystalline lens opacities were observed after bioptics. Conclusions: This study demonstrates that TICL implantation provides reliable visual outcomes similar to bioptics. The advantages of TICL implantation are a more stable visual outcome and the elimination of laser treatments and their inherent risks.Keywords
This publication has 19 references indexed in Scilit:
- Visual Performance after Implantable Collamer Lens Implantation and Wavefront-Guided Laser In Situ Keratomileusis for High MyopiaAmerican Journal of Ophthalmology, 2009
- Postoperative Astigmatism and Axis Stability After Implantation of the STAAR Toric Implantable Collamer LensJournal of Refractive Surgery, 2009
- Changes in Iridocorneal Angle Structure and Trabecular Pigmentation With STAAR Implantable Collamer Lens During 2 YearsJournal of Refractive Surgery, 2009
- Comparison of Collamer toric contact lens implantation and wavefront-guided laser in situ keratomileusis for high myopic astigmatismJournal of Cataract & Refractive Surgery, 2008
- Toric Implantable Collamer Lens for Moderate to High Myopic AstigmatismOphthalmology, 2007
- Long-term results of implantation of phakic posterior chamber intraocular lensesJournal of Cataract & Refractive Surgery, 2004
- United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopiaOphthalmology, 2004
- Outcome after treatment of ametropia with implantable contact lensesOphthalmology, 2003
- Safety of posterior chamber phakic intraocular lenses for the correction of high myopiaOphthalmology, 2001