Iopromide one‐sample clearance as a measure of glomerular filtration rate
Authors:
- 1 March 2002
- journal article
- clinical trial
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 22 (2) , 99-107
Abstract
Objective: The pharmacokinetics of iopromide were analysed using a two‐compartment model. The optimal point of time for blood withdrawal for calculation of a one‐sample clearance was determined. Methods: Plasma concentration of iodine was measured up to 8 h postinjection (p.i.) in 62 adult patients who received 120 ml iopromide for computed tomography (CT). A two exponential function was fitted by a weighted least error square method. As reference method, clearance was calculated from this function and the injected amount of iodine. Empirical parameters for calculation of one‐sample clearance were determined. This one‐sample clearance was compared with one‐sample clearance calculated according to formulas developed for Tc99m‐DTPA by Jacobsson as well as a two sample method. Results: Total distribution volume of iopromide was calculated as 0·242 Lkg−1± 5·9%. A high correlation of all one‐sample method and the two‐sample method with reference to clearance was found. Best estimation of iopromide plasma clearance was achieved by determining one‐sample clearance 270 or 285 min p. i. with SDy.x of 5·8 ml min–1. Conclusions: After administration of 120 ml iopromide, one‐sample plasma clearance can be calculated with low estimation error taking one blood sample at an appropriate time point. Late phase pharmacokinetics of iopromide found in the present study showed to be virtually identical to results published for iohexol and Tc99m‐DTPA.Keywords
This publication has 14 references indexed in Scilit:
- Evaluation of iohexol as a marker for the clinical measurement of glomerular filtration rate in dogsResearch in Veterinary Science, 1996
- Biochemical Characterization of X-ray Contrast MediaInvestigative Radiology, 1996
- Dose proportionality of iopromide pharmacokinetics and tolerability after IV injection in healthy volunteersEuropean Journal of Clinical Pharmacology, 1994
- Iohexol Clearance for the Determination of Glomerular Filtration Rate in Clinical Practice: Evidence for a New Gold StandardJournal of Urology, 1991
- Measurement of the Plasma Clearance of Urographic Contrast Media for the Determination of Glomerular Filtration RateJournal of Urology, 1988
- Contrast media as markers for glomerular filtration: A pharmacokinetic comparison of four agentsScandinavian Journal of Clinical and Laboratory Investigation, 1988
- Determination of 99mTc‐DTPA clearance by a single plasma sample methodClinical Physiology and Functional Imaging, 1986
- An Automated Fluorescent Excitation Analysis System for Medical ApplicationsInvestigative Radiology, 1976
- A Simple Method for the Determination of Glomerular Filtration RateScandinavian Journal of Clinical and Laboratory Investigation, 1972
- CLINICAL CALORIMETRYArchives of internal medicine (1908), 1916