Stabilization and Sensitization of Stainless Steels
Authors:
- 9 March 1997
- conference paper
- Published by Association for Materials Protection and Performance (AMPP)
- p. 1-13
Abstract
This investigation examines the intergranular corrosion resistance of both welded and unwelded type 304, 304L, 321, 321L, and 347 alloys after various sensitizing and or stabilizing heat treatments. The intergranular corrosion resistance was characterized using ASTM A262 test methods and the double loop electrochemical potentiodynamic reactivation testing (EPR). The results show that stabilization by itself is not sufficient to render austentic stainless steel immune to sensitization. The EPR testing demonstrates that the double loop (ir/ia) parameters for all alloys do correlate well with corrosion rates measured with the ASTM A262 Practice B test.Keywords
This publication has 6 references indexed in Scilit:
- The Double Loop Reactivation Method for Detecting Sensitization in AISI 304 Stainless SteelsCorrosion, 1984
- Potentiodynamic Reactivation Method for Detecting Sensitization in AISI 304 and 304L Stainless SteelsCorrosion, 1984
- Testing the Susceptibility of Stainless Steel to Intergranular Corrosion by a Reactivation MethodCorrosion, 1975
- Development of Pitting Resistant Fe-Cr-Mo AlloysCorrosion, 1974
- A Study Designed to Explain the Creep-Rupture Strength of Type 321 (“18Cr-8Ni+Ti”) Superheater TubingJournal of Engineering for Power, 1963
- The Mechanism of Knife-Line Attack In Welded Type 347 Stainless SteelCorrosion, 1951