Scan quality effect on glaucoma discrimination by glaucoma imaging devices
Authors:
- J S SchumanJSJ S Schuman
- H IshikawaHIH Ishikawa
- L KagemannLKL Kagemann
- for the Advanced Imaging in Glaucoma Study GroupFGfor the Advanced Imaging in Glaucoma Study Group
- 18 August 2009
- journal article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 93 (12) , 1580-1584
Abstract
Aim: To evaluate, within ocular imaging scans of acceptable quality as determined by manufacturers’ guidelines, the effects of image quality on glaucoma discrimination capabilities. Methods: One hundred and four healthy and 75 glaucomatous eyes from the Advanced Imaging in Glaucoma Study (AIGS) were imaged with GDx-VCC, HRT II and StratusOCT. Quality score (QS⩾8), pixel standard deviation (SD⩽50) and signal strength (SS⩾5) were used as quality parameter cut-offs, respectively. GDx nerve fibre indicator (NFI) and HRT Moorfields regression analysis (MRA) classifications and OCT mean retinal nerve fibre layer (RNFL) thickness were used as the discriminatory parameters. Logistic regression models were used to model the dichotomous clinical classification (healthy vs glaucoma) as a function of image-quality parameters and discriminatory parameters. Results: Quality parameter covariates were statistically non-significant for GDx and HRT but had an inverse effect on OCT in predicting disease (a higher SS had a lower probability of glaucoma). Age was a significant covariate for GDx and HRT, but not OCT, while ethnicity and interaction between the image quality and the institute where scans were acquired were significant covariates in the OCT models. Conclusion: Scan quality within the range recommended as acceptable by the manufacturer of each imaging device does not affect the glaucoma discriminating ability of GDx or HRT but does affect Stratus OCT glaucoma discrimination.Keywords
This publication has 22 references indexed in Scilit:
- Comparison of Parameters from Heidelberg Retina Tomographs 2 and 3Ophthalmology, 2008
- Effect of Corneal Drying on Optical Coherence TomographyOphthalmology, 2006
- Errors in Retinal Thickness Measurements Obtained by Optical Coherence TomographyOphthalmology, 2006
- A new quality assessment parameter for optical coherence tomographyBritish Journal of Ophthalmology, 2006
- Diagnostic Ability of Optical Coherence Tomography with a Normative Database to Detect Localized Retinal Nerve Fiber Layer DefectsOphthalmology, 2005
- Factors affecting the test-retest variability of Heidelberg retina tomograph and Heidelberg retina tomograph II measurementsBritish Journal of Ophthalmology, 2005
- Diagnostic accuracy of the GDx VCC for glaucomaOphthalmology, 2004
- Optical coherence tomography (oct) macular and peripapillary retinal nerve fiber layer measurements and automated visual fieldsAmerican Journal of Ophthalmology, 2004
- Model Selection and Multimodel Inference: A Practical Information-Theoretic ApproachThe Journal of Wildlife Management, 2003
- A new look at the statistical model identificationIEEE Transactions on Automatic Control, 1974