Aortic arch replacement using a four-branched aortic arch graft
Open Access
- 1 January 2002
- journal article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 21 (1) , 89-91
Abstract
Surgical repair for aortic arch aneurysms is associated with considerable mortality and morbidity. Adequate brain protection is essential. Experience of aortic arch repair in six patients using a four-branched arch graft is described. There were two emergency and three reoperations. One patient had ruptured aneurysm. Hypothermic cardiopulmonary bypass (18–22°C) was employed. A four-branched polymer albumin-coated arch graft was used. The fourth branch of the graft was used for secondary arterial cannulation to ensure continuous brain circulation. One hospital death occurred. No permanent neurological event occurred. The four-branched arch graft facilitates fashioning arch branch anastomoses and provides better brain protection.Keywords
This publication has 5 references indexed in Scilit:
- Improved results of atherosclerotic arch aneurysm operations with a refined techniqueThe Journal of Thoracic and Cardiovascular Surgery, 2001
- Unilateral Antegrade Cerebral Perfusion Through the Right Axillary Artery Provides Uniform Flow Distribution to Both Hemispheres of the Brain : A Magnetic Resonance and Histopathological Study in PigsCirculation, 1999
- Antegrade selective cerebral perfusion in operations on the proximal thoracic aortaThe Annals of Thoracic Surgery, 1999
- Aortic arch operation: Current treatment and resultsThe Annals of Thoracic Surgery, 1995
- Replacement of the transverse aortic arch during emergency operations for type A acute aortic dissectionThe Journal of Thoracic and Cardiovascular Surgery, 1988