Off-Resonance Angiography: A New Method to Depict Vessels—Phantom and Rabbit Studies

Authors:
  • SSSaurabh Shah
    Saurabh Shah
  • EVEvert-Jan Vonken
    Evert-Jan Vonken
  • WGWesley D. Gilson
    Wesley D. Gilson
  • LTLijun Tang
    Lijun Tang
  • DKDara L. Kraitchman
    Dara L. Kraitchman
  • RBRaymond C. Boston
    Raymond C. Boston
  • DSDavid E. Sosnovik
    David E. Sosnovik
  • RWRobert G. Weiss
    Robert G. Weiss
  • RWRalph Weissleder
    Ralph Weissleder

Abstract
Purpose: To evaluate the utility of inversion recovery with on-resonant water suppression (IRON) in combination with injection of the long-circulating monocrystalline iron oxide nanoparticle (MION)-47 for contrast material–enhanced magnetic resonance (MR) angiography. Materials and Methods: Experiments were approved by the institutional animal care committee. Eleven rabbits were imaged at baseline before injection of a contrast agent and then serially 5–30 minutes, 2 hours, 1 day, and 3 days after a single intravenous bolus injection of 80 μmol of MION-47 per kilogram of body weight (n = 6) or 250 μmol/kg MION-47 (n = 5). Conventional T1-weighted MR angiography and IRON MR angiography were performed on a clinical 3.0-T imager. Signal-to-noise and contrast-to-noise ratios were measured in the aorta of rabbits in vivo. Venous blood was obtained from the rabbits before and after MION-47 injection for use in phantom studies. Results: In vitro blood that contained MION-47 appeared signal attenuated on T1-weigh...