Analysis on the accuracy of CT-guided radioactive I-125 seed implantation with 3D printing template assistance in the treatment of thoracic malignant tumors
Authors:
Open Access
- 5 August 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 62 (5) , 910-917
Abstract
This article analyzes the accuracy of needle track and dose of a 3-dimensional printing template (3DPT) in the treatment of thoracic tumor with radioactive I-125 seed implantation (RISI). A total of 28 patients were included. The technical process included: (i) preoperative CT positioning, (ii) preoperative planning design, (iii) 3DPT design and printing, (iv) 3DPT alignment, (v) puncture and seed implantation. The errors of needle position and dosimetric parameters were analyzed. A total of 318 needles were used. The mean errors in needle depth, needle insertion point, needle tip and needle angle were 0.52 ± 0.48 cm, 3.4 ± 1.7 mm, 4.4 ± 2.9 mm and 2.8 ± 1.7°, respectively. The differences between actual needle insertion angle and needle depth and those designed in the preoperative were statistically significant (p < 0.05). The mean values of all the errors of the chest wall cases were smaller than those of the lungs, and the differences were statistically significant (p < 0.05). There was no significant difference between the D90 calculated in the postoperative plan and those designed in the preoperative and intraoperative plans (p > 0.05). Some dosimetric parameters of preoperative plans such as V100, V200, CI and HI were not consistent with that of preoperative plans, and the difference was statistically significant (p < 0.05). However, there were no statistical difference in the dosimetric parameters between the postoperative plans and intraoperative plans (p > 0.05). We conclude that for thoracic tumors, even under the guidance of 3DPT, there will be errors. The plan should be optimized in real time during the operation.Keywords
Funding Information
- National Key Research and Development Program of China (2019YFB1311300, 2019YFB1311305)
This publication has 20 references indexed in Scilit:
- The investigation of 125I seed implantation as a salvage modality for unresectable pancreatic carcinomaJournal of Experimental & Clinical Cancer Research, 2013
- A digital model individual template and CT-guided 125I seed implants for malignant tumors of the head and neckJournal of Radiation Research, 2012
- Permanent Implantation of Iodine-125 Seeds as a Salvage Therapy for Recurrent Head and Neck Carcinoma After RadiotherapyCancer Investigation, 2012
- CT-guided interstitial brachytherapy of inoperable non-small cell lung cancerLung Cancer, 2011
- AAPM recommendations on dose prescription and reporting methods for permanent interstitial brachytherapy for prostate cancer: Report of Task Group 137Medical Physics, 2009
- The biological effect of 125I seed continuous low dose rate irradiation in CL187 cellsJournal of Experimental & Clinical Cancer Research, 2009
- Dosimetric effects of needle divergence in prostate seed implant using and radioactive seedsMedical Physics, 2000
- A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostateInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1997
- 97 The stepping source dosimetry system as an extension of the Manchester systemRadiotherapy and Oncology, 1996
- Quantitative assessment of interstitial implantsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1991