Phase‐contrast echo‐planar MR imaging: Real‐time quantification of plow and velocity patterns in the thoracic vessels induced by valsalva's maneuver
Authors:
- 1 November 1995
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 5 (6) , 648-655
Abstract
Although the clinical manifestations of Valsalva's maneuver are well known, the associated hemodynamic changes in the great vessels have not been extensively studied and documented. In each of six healthy subjects, we evaluated three “quasi‐steady‐state” phases of Valsalva's maneuver: (1) during normal respiration, (2) during late strain, and (3) 4 seconds after strain release. Continuous flow, velocity, and cross‐sectional area measurements were obtained in the superior vena cava, pulmonary trunk, and thoracic aorta with single‐shot echo‐planar MR imaging (EPI) with velocity‐encoded gradients, which provided 256 Images in 5 seconds, yielding 26 velocity‐encoded images per second. In the superior vena cava, Valsalva's maneuver induced an 11% decrease in average flow volume, a 102% increase in peak flow velocity, a 156% increase in the time velocity integral, and a 37% decrease in cross‐sectional area. MR velocity measurements agreed with echo‐cardiographic data and supplied additional information on flow and morphology. EPI showed a reduction in venous return during Valsalva's maneuver by simultaneously assessing flow, velocity, and vessel morphology; this technique appears to be useful in the analysis of flow dynamics of the great vessels.Keywords
This publication has 22 references indexed in Scilit:
- Evaluation of ultrafast phase-contrast imaging in the thoracic aortaMagnetic Resonance Materials in Physics, Biology and Medicine, 1995
- Interleaved echo planar flow quantitationMagnetic Resonance in Medicine, 1994
- Venous changes occurring during the valsalva maneuver: Evaluation by intravascular ultrasoundThe American Journal of Cardiology, 1994
- Interleaved echo planar phase contrast angiographyMagnetic Resonance in Medicine, 1994
- Aortic valve pressure gradients in patients with aortic valve stenosis: quantification with velocity-encoded cine MR imaging.American Journal of Roentgenology, 1993
- Phase velocity mapping with a real time line scan techniqueMagnetic Resonance in Medicine, 1993
- Real‐time flow measurements using echo‐planar imagingMagnetic Resonance in Medicine, 1991
- Doppler echocardiographic flow velocity measurements in the superior vena cava during the valsalva maneuver in normal subjectsThe American Journal of Cardiology, 1990
- In Vivo Validation of MR Velocity ImagingJournal of Computer Assisted Tomography, 1987
- The valsalva maneuver as a test of cardiac functionThe American Journal of Medicine, 1957