Feasibility and accuracy of new insertion technique of S1 transpedicular screw. Computed tomography-based morphometric analysis
- 1 September 2016
- journal article
- Published by VM Media Group sp. z o.o in Neurologia i Neurochirurgia Polska
- Vol. 50 (5) , 363-369
Abstract
To assess feasibility and accuracy of a new insertion technique of S1 transpedicular screw. Transpedicular stabilization in the first sacral vertebra (S1) is a technically demanding surgical procedure with inherent risk of loosening of the implant. A modification of the technique was recently proposed, along with the analytical verification which was performed based on the available literature. In the study, we performed radiological assessment of screws inserted into the S1 using the classical and modified techniques. The analysis was performed in two parts. The first part was performed on eight cadaver specimens after implantation of the screws. In the second part, we used computed tomography images of patients with degenerative disk disease with a superimposed representation of screws. The thickness of the posterior cortex adherent to the screws, screw trajectory and their position with regard to the spinal canal was measured. The area of posterior cortex in contact with the screws was also calculated. The contact length and area was found to be two times greater for screws introduced with the modified technique. The convergence angle was comparable between the techniques, despite the shift of entry point. There was no canal breach, although with the modified technique the screws passed closer to the spinal canal. The modified technique is considered safe. In this technique, the screws pass through a thicker portion of the posterior cortex compared to the classical technique that aims at improving the stability of the fixation.Keywords
This publication has 14 references indexed in Scilit:
- Evidence-based support for S1 transpedicular screw entry point modificationJournal of Orthopaedic Surgery and Research, 2014
- Morphometric Measurement of Cortical Bone Trajectory for Lumbar Pedicle Screw Insertion Using Computed TomographyJournal of Spinal Disorders & Techniques, 2013
- Espondilolistese traumática do áxis: epidemiologia, conduta e evoluçãoActa Ortopedica Brasileira, 2012
- Spinal alignment in surgical, multisegmental, transpedicular correction of adolescent idiopathic scoliosisMedical Science Monitor, 2012
- Bone Density and Cortical Thickness in Normal, Osteopenic, and Osteoporotic SacraJournal of Osteoporosis, 2010
- A biomechanical comparison of polymethylmethacrylatereinforced and expansive pedicle screws in pediclescrew revisionsActa Orthopaedica et Traumatologica Turcica, 2009
- A Stronger Bicortical Sacral Pedicle Screw Fixation Through The S1 EndplateSpine, 2005
- Preoperative CT Determination of Angles for Sacral Screw PlacementSpine, 1994
- The Effects of Depth of Penetration, Screw Orientation, and Bone Density on Sacral Screw FixationSpine, 1993
- Surgical Anatomy of the SacrumSpine, 1991