Preconcentration of mercury(II) from waters using glycidyl methacrylate-methyl methacrylate-divinyl benzene terpolymer with diethylenetriamine tetra acetic acid functions prior to inductively coupled plasma mass spectrometric determination
Open Access
- 1 December 2016
- journal article
- research article
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (57) , 27834-27842
Abstract
A novel sorbent, glycidyl methacrylate (GMA)-methyl methacrylate (MMA)-divinylbenzene (DVB) terpolymer functionalized with diethylenetriamine tetraacetic acid (DTTA), has been used for the sorption and preconcentration of Hg2+ from waters prior to its determination by inductively coupled plasma mass spectrometry. Various parameters such as solution pH, contact time, and sorbent amount were studied. Optimum sorption conditions were determined as pH of 7, contact time of 60 minutes, and sorbent amount/solution volume ratio of 1.5 mg mL−1. Batch-type equilibration studies have shown that the novel sorbent can be employed at a pH range resulting in quantitative sorption (>95%) at pH 4.0–8.0. For the quantitative elution of Hg2+ from the sorbent, 1.0 M HCl was used. Langmuir isotherm model was found to characterize the uptake of Hg2+ by the novel sorbent. In addition, it was observed that the sorbent effectively removed Hg2+ ion even in the presence of several competitor ions (Pb2+, Cu2+, Zn2+, Fe3+, Ca2+, Mg2+, Ba2+, Ni2+, Al3+, Co2+, Mn2+, and Cd2+) with ≥99% removal. The validity of the method was verified both through the analysis of certified reference materials (BCR 422 and NIST 1547) and by spike recovery experiments. A recovery of ≥93% was obtained for ultrapure, tap and bottled drinking water samples even with a preconcentration factor of 100. Moreover, a good agreement was found for the results obtained with the proposed method and the certified values.Keywords
Funding Information
- Ege Üniversitesi
This publication has 28 references indexed in Scilit:
- Determination of Mercury(II) in the Presence of Methylmercury after Preconcentration Using Poly(acrylamide) Grafted onto Cross-linked Poly(4-vinyl pyridine): Application to Mercury SpeciationAnalytical Sciences, 2011
- Global Biogeochemical Cycling of Mercury: A ReviewAnnual Review of Environment and Resources, 2009
- Trace mercury determination in drinking and natural water samples by room temperature ionic liquid based-preconcentration and flow injection-cold vapor atomic absorption spectrometryJournal of Hazardous Materials, 2009
- Preconcentration techniques for the determination of mercury species in natural watersTrAC Trends in Analytical Chemistry, 2009
- Determination of mercury in ash and soil samples by oxygen flask combustion method–Cold vapor atomic fluorescence spectrometry (CVAFS)Journal of Hazardous Materials, 2008
- Determination of trace levels of mercury in aqueous solutions by inductively coupled plasma atomic emission spectrometry: Elimination of the ‘memory effect’Microchemical Journal, 2007
- Mercury Exposure and Public HealthPediatric Clinics of North America, 2007
- Mercury emissions to the atmosphere from anthropogenic sources in Europe in 2000 and their scenarios until 2020Science of The Total Environment, 2006
- Metals, Toxicity and Oxidative StressCurrent Medicinal Chemistry, 2005
- Mercury in the Environment: Effect on Health and ReproductionReviews on Environmental Health, 2005