Prevention of Wear and Osteolysis
Authors:
- Remy NizardRNRemy Nizard
- Moussa HamadoucheMHMoussa Hamadouche
- Didier HannoucheDHDidier Hannouche
- Laurent SedelLSLaurent Sedel
- 1 December 2001
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 393 (393) , 85-93
Abstract
Alumina-on-alumina bearings in total hip replacement have been used for 30 years. Excellent tribologic properties and extra low debris generation could, in theory, provide an answer to osteolysis. A review of the authors' experience with alumina-on-alumina bearings showed that, except in a few bearings that had been loose for a long time, osteolysis was not a problem. Although the cemented titanium stem and the alumina-on-alumina couple were not a problem, fixation of the socket had to be improved. To improve the socket fixation system and to avoid the use of a cemented titanium stem that may have created problems in the long-term, a new design was introduced in 1997. The current authors present the preliminary results of the first 96 hips with cementless fully-coated hydroxyapatite titanium alloy stems and sockets, 32-mm alumina femoral head, and alumina liner, both held with a Morse taper. Ninety-six consecutive hips in 89 patients (57 males, 32 females) with a median age of 46 years (range, 14-72 years) were analyzed. One socket was revised at 4 months because of poor primary stability in a patient with a severe acetabular fracture. One patient experienced a traumatic fracture of the implanted femur 3 weeks after surgery. The mean followup was 16 months (range, 4-38 months). One patient died from rupture of an aneurysm. Ninety-three hips in 86 patients were assessed regarding the clinical and radiologic ratings. Two patients (two hips) were interviewed by telephone. The Merle d'Aubigné rating system was 18 in 65 hips (59 patients), 17 in 25 hips (25 patients), and 16 in three hips (three patients) mainly related to a previous disability including limp, sciatic palsy, or stiffness. Examination of 93 available radiographs revealed no ostelolysis, no radiolucent lines at the last examination, and no subsidence. The level of excellent results, even in this young population, and lack of osteolysis and wear are encouraging, even if the followup is too short to allow any conclusions to be made.Keywords
This publication has 21 references indexed in Scilit:
- Alumina-on-Alumina Total Hip Prostheses in Patients 40 Years of Age or YoungerClinical Orthopaedics and Related Research, 2000
- Press-Fit Metal-Backed Alumina SocketsClinical Orthopaedics and Related Research, 2000
- Alumina Ceramic Bearings for Hip EndoprosthesesClinical Orthopaedics and Related Research, 2000
- Cementless bulk alumina socketThe Journal of Arthroplasty, 1999
- Mittelmeier ceramic—ceramic prosthesis after 10 yearsThe Journal of Arthroplasty, 1996
- Ceramic Femoral Head Fractures in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1996
- The use of dense alumina–alumina ceramic combination in total hip replacementJournal of Biomedical Materials Research, 1988
- Tissue reaction to ceramic implant materialJournal of Biomedical Materials Research, 1979
- Ectopic Ossification Following Total Hip ReplacementJournal of Bone and Joint Surgery, 1973
- Biological activity and histocompatibility of dense Al2 O3/MgO ceramic implants in ratsJournal of Biomedical Materials Research, 1973