Application of a 3D Human Cornea‐Like Epithelium for Eye Irritation Assessment of Contact Lens Solutions
Authors:
- 27 May 2025
- journal article
- Published by Wiley in Journal of Applied Toxicology
- Vol. 45 (10) , 1984-1994
Abstract
Currently, medical device eye irritation testing relies on the Draize eye test in rabbits, which presents significant challenges regarding animal welfare and variations across laboratories. This research explores the application of the commercially available three‐dimensional reconstructed human corneal epithelial tissue (Skinovo‐Ocular) in eye irritation evaluation. The model is developed by culturing immortalized human corneal epithelial cells at a liquid‐air interface, resembling the morphology and induction of biological indicators found in human corneal tissue. We evaluated the eye irritation effect of 30 minimum reference chemicals according to OECD Performance Standards. The results revealed a sensitivity of 100%, specificity of 66.7%, and accuracy of 83.3%, indicating predictive performance comparable to other reference methods. Furthermore, we conducted analyses including trans‐epithelial electrical resistance, cytokine secretion, and histology, thereby enhancing our understanding of the mechanisms underlying eye irritation assessment in this model. Additionally, we tested various contact lens solutions and compared the results with rabbit in vivo experiments, demonstrating the model's potential for analyzing the eye irritation of mixtures. This model shows promise as an alternative for eye irritation analysis of medical devices, further reducing the reliance on experimental animals.Keywords
This publication has 22 references indexed in Scilit:
- Development of a defined approach for eye irritation or serious eye damage for liquids, neat and in dilution, based on cosmetics Europe analysis of in vitro STE and BCOP test methodsToxicology in Vitro, 2019
- Me-too validation study for in vitro eye irritation test with 3D-reconstructed human cornea epithelium, MCTT HCETMToxicology in Vitro, 2019
- SkinEthic™ HCE Eye Irritation Test: Similar performance demonstrated after long distance shipment and extended storage conditionsToxicology in Vitro, 2018
- Pre-validation of an in vitro skin irritation test for medical devices using the reconstructed human tissue model EpiDerm™Toxicology in Vitro, 2018
- SkinEthic™ RHE for in vitro evaluation of skin irritation of medical device extractsToxicology in Vitro, 2018
- Evaluation of ocular irritancy of coal-tar dyes used in cosmetics employing reconstructed human cornea-like epithelium and short time exposure testsFood and Chemical Toxicology, 2017
- Multi-laboratory validation of SkinEthic HCE test method for testing serious eye damage/eye irritation using liquid chemicalsToxicology in Vitro, 2016
- Occludin gene expression as an early in vitro sign for mild eye irritation assessmentToxicology in Vitro, 2010
- Prevalidation of a new in vitro reconstituted human cornea model to assess the eye irritating potential of chemicalsToxicology in Vitro, 2006
- Eye irritation of low-irritant cosmetic formulations: correlation of in vitro results with clinical data and product compositionFood and Chemical Toxicology, 2005