Two-colour pyrometer for the statistical measurement of the surface temperature of particles under thermal plasma conditions
Authors:
- J MishinJMJ Mishin
- M VardelleMVM Vardelle
- J LesinskiJLJ Lesinski
- P FauchaisPFP Fauchais
- 1 June 1987
- journal article
- Published by IOP Publishing in Journal of Physics E: Scientific Instruments
- Vol. 20 (6) , 620-625
Abstract
No abstract availableKeywords
This publication has 7 references indexed in Scilit:
- Two-colour pyrometer measurement of the temperature of individual combusting particlesJournal of Physics E: Scientific Instruments, 1985
- Transient heat conduction under plasma conditionsInternational Journal of Heat and Mass Transfer, 1983
- Diagnostics Under Thermal Plasma ConditionsMRS Proceedings, 1983
- Les générateurs à plasmaRevue de Physique Appliquée, 1981
- Measurements of the Plasma and Condensed Particles Parameters in a DC Plasma JetIEEE Transactions on Plasma Science, 1980
- Temperature distributions of solid particles in a plasma streamRevue de Physique Appliquée, 1977
- Measurement of Emission and Absorption of Radiation by an Argon PlasmaThe Physics of Fluids, 1967