Ultrasensitive Detection of PSA Using Antibodies in Crowding Polyelectrolyte Multilayers on a Silicon Nanowire Field-Effect Transistor
Authors:
- Galina V. PresnovaGPGalina V. Presnova
- Denis E. PresnovDPDenis E. Presnov
- Mariya M. UlyashovaMUMariya M. Ulyashova
- Ilia I. TsiniaikinITIlia I. Tsiniaikin
- Artem S. TrifonovATArtem S. Trifonov
- Ekaterina V. SkorbESEkaterina V. Skorb
- Vladimir A. KrupeninVKVladimir A. Krupenin
- Oleg V. SnigirevOSOleg V. Snigirev
- Maya Yu. RubtsovaMRMaya Yu. Rubtsova
Open Access
Abstract
Immunosensors based on field-effect transistors with nanowire channels (NWFETs) provide fast and real-time detection of a variety of biomarkers without the need for additional labels. The key feature of the developed immunosensor is the coating of silicon NWs with multilayers of polyelectrolytes (polyethylenimine (PEI) and polystyrene sulfonate (PSS)). By causing a macromolecular crowding effect, it ensures the “soft fixation” of the antibodies into the 3-D matrix of the oppositely charged layers. We investigated the interaction of prostate-specific antigen (PSA), a biomarker of prostate cancer, and antibodies adsorbed in the PEI and PSS matrix. In order to visualize the formation of immune complexes between polyelectrolyte layers using SEM and AFM techniques, we employed a second clone of antibodies labeled with gold nanoparticles. PSA was able to penetrate the matrix and concentrate close to the surface layer, which is crucial for its detection on the nanowires. Additionally, this provides the optimal orientation of the antibodies’ active centers for interacting with the antigen and improves their mobility. NWFETs were fabricated from SOI material using high-resolution e-beam lithography, thin film vacuum deposition, and reactive-ion etching processes. The immunosensor was characterized by a high sensitivity to pH (71 mV/pH) and an ultra-low limit of detection (LOD) of 0.04 fg/mL for PSA. The response of the immunosensor takes less than a minute, and the measurement is carried out in real time. This approach seems promising for further investigation of its applicability for early screening of prostate cancer and POC systems.Keywords
Funding Information
- MSU Program
This publication has 50 references indexed in Scilit:
- Protein adsorption and covalent bonding to silicon nitride surfaces modified with organo-silanes: Comparison using AFM, angle-resolved XPS and multivariate ToF-SIMS analysisColloids and Surfaces B: Biointerfaces, 2013
- Proteins and polyelectrolytes: A charged relationshipCurrent Opinion in Colloid & Interface Science, 2012
- Effect of Nanowire Number, Diameter, and Doping Density on Nano-FET Biosensor SensitivityACS Nano, 2011
- Optimal signal-to-noise ratio for silicon nanowire biochemical sensorsApplied Physics Letters, 2011
- Quantifying signal changes in nano-wire based biosensorsNanoscale, 2010
- Direct observation of single-charge-detection capability of nanowire field-effect transistorsNature Nanotechnology, 2010
- Importance of the Debye Screening Length on Nanowire Field Effect Transistor SensorsNano Letters, 2007
- Normal and torsional spring constants of atomic force microscope cantileversReview of Scientific Instruments, 2004
- Functional Nanoscale Electronic Devices Assembled Using Silicon Nanowire Building BlocksScience, 2001
- A novel description of ISFET sensitivity with the buffer capacity and double-layer capacitance as key parametersSensors and Actuators B: Chemical, 1995