Analysis of PMSG under stator turn to turn fault using winding function theory
- 1 December 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 116-121
Abstract
This paper includes a different approach to analyze the turn-to-turn fault in stator winding of 3phase Permanent Magnet Synchronous Generator. For better life cycle of PMSG it is very much needed to understand the abnormal behavior for earlier protection. Using Winding Function Approach, the abnormal behavior of shorted stator phase current, fault current and change of values of machine parameters has been described in detail and based on this method simulation result will be provided by using dynamic equations. For better understanding, comparison between healthy and faulty PMSG will be done and the analytical approach and simulated results will be verified with practical experiment.Keywords
This publication has 7 references indexed in Scilit:
- Modelling and simulation of faults in synchronous generators for robust numerical protectionInternational Journal of Power and Energy Conversion, 2012
- The Internal Fault Analysis of Brushless DC Motors Based on the Winding Function TheoryIEEE Transactions on Magnetics, 2009
- Permanent-Magnet Synchronous Motor Magnet Designs With Skewing for Torque Ripple and Cogging Torque ReductionIEEE Transactions on Industry Applications, 2009
- Fast Single-Turn Sensitive Stator Inter-Turn Fault Detection of Induction Machines Based on Positive and Negative Sequence Third Harmonic Components of Line Currents2008
- Stator-winding fault diagnosis of PM brushless DC motor drives2003
- Novel frequency domain based technique to detect incipient stator inter-turn faults in induction machines2002
- The detection of inter-turn short circuits in the stator windings of operating motorsIEEE Transactions on Industrial Electronics, 2000