Reliability of a Novel Hematological Malignancy Specific Patient-Reported Outcome Measure: HM-PRO
Authors:
Open Access
- 20 October 2020
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Pharmacology
- Vol. 11, 571066
Abstract
Background: Patients’ experience of symptoms often goes undetected during consultation in an outpatient clinic, and the use of a patient-reported outcome measure (PRO) in such a setting could be useful to aid treatment decision-making. A new PRO measure, the HM-PRO (Hematological Malignancy Specific Patient-Reported Outcome Measure) has been recently developed to evaluate hematological malignancy (HM) patients’ health-related quality of life (HRQoL) and their symptom experience in daily clinical practice as well as in research. The objectives of the study were to assess: the internal consistency of the scores for Part A (impact) and its four domains (physical behavior; social well-being; emotional behavior; and eating and drinking habits) and Part B (signs and symptoms); and the test-retest reliability of the individual items of the newly developed hematological malignancy specific composite measure, the HM-PRO. Methods: This was a prospective longitudinal observational study where 150 patients with different HMs and different stage of disease (male n = 98 (65.3%); mean age 64.9 ± 14.4 years, range 17.9–89.2 years; mean time since diagnosis 3.7 ± 4.9 years, range 0.04–25.8 years) completed the HM-PRO at baseline (assessment 1 at t1) and after 7 days (assessment 2 at t2). Data analysis was performed using IBMSPSS 23 statistical software. Results: The Cronbach’s alpha estimates of the HM-PRO for both assessment points (t1 and t2) were above 0.9 for Part A, and above 0.8 for Part B, showing strong stability of the measurement. The level of agreement for the reproducibility between the two assessments, using intra-class correlation coefficients (ICC), was very strong with Part A: ICC = 0.93 (95% CI = 0.90–0.95), and Part B: ICC = 0.91 (0.88–0.93). The ICC for the four domains of Part A ranged from 0.85–0.91. The ICC was greater than 0.8 for overall score of Part A and Part B for all the 10 diagnoses, confirming strong reliability. Conclusion: This study clearly indicates that the HM-PRO possesses strong test-retest reliability for both Part A and Part B. The Cronbach’s alpha confirmed acceptable internal consistency. The extensive reliability testing described in this study supports the generic nature of the HM-PRO for use in hematological malignancies in both routine clinical practice, to aid treatment decisions, as well as in research.Keywords
This publication has 28 references indexed in Scilit:
- Making sense of Cronbach's alphaInternational Journal of Medical Education, 2011
- Internal Consistency, Retest Reliability, and Their Implications for Personality Scale ValidityPersonality and Social Psychology Review, 2010
- Health related quality of life in a nationally representative sample of haematological patientsEuropean Journal of Haematology, 2009
- Psychosocial QOL is an independent predictor of overall survival in newly diagnosed patients with multiple myelomaEuropean Journal of Haematology, 2008
- What Is Sufficient Evidence for the Reliability and Validity of Patient-Reported Outcome Measures?Value in Health, 2007
- Quality of life in chronic lymphocytic leukemia: an international survey of 1482 patientsBritish Journal of Haematology, 2007
- Quality of life among long‐term non‐Hodgkin lymphoma survivorsCancer, 2007
- Quality of life of patients with chronic lymphocytic leukemia: results of a longitudinal investigation over 1 yrEuropean Journal of Haematology, 2004
- Forming inferences about some intraclass correlation coefficients.Psychological Methods, 1996
- Coefficient Alpha and the Internal Structure of TestsPsychometrika, 1951