Configuration of Corneal Trephine Opening Using Five Different Trephines in Human Donor Eyes
Authors:
- George O. WaringGWGeorge O. Waring
- 1 September 1988
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 106 (9) , 1228-1233
Abstract
• In this laboratory study, we used five different corneal trephines on 60 fresh human donor eyes with controlled intraocular pressure to study the variation in the size and shape of the trephine openings. With all trephines, the average diameter of the button was larger than the diameter of the trephine at the epithelial side (mean difference, 0.21 mm; range, 0.06 to 0.35 mm) and the endothelial side (mean difference, 0.42 mm; range, 0.13 to 0.79 mm), presumably because the corneal tissue protruded into the trephine during cutting. The trephines that produced the most uniform opening were a nondisposable suction trephine and a freestanding disposable blade, but they caused some undercutting.Keywords
This publication has 5 references indexed in Scilit:
- Changes in Corneal Curvature Induced by Sutures and IncisionsAmerican Journal of Ophthalmology, 1984
- Modulation of Postkeratoplasty Astigmatism by Surgical and Suturing TechniquesInternational Ophthalmology Clinics, 1983
- Der Einfluß der Bedingungen bei der Trepanation von isolierten Schweinehornhäuten auf die Schnittgeschwindigkeit und SchnittzeitGraefe's Archive for Clinical and Experimental Ophthalmology, 1982
- An Analysis and Interpretation of Refractive Errors after Penetrating KeratoplastyOphthalmology, 1981
- Variation in Corneal Graft Size Related to Trephine TechniqueArchives of Ophthalmology (1950), 1979