Can energy expenditure be accurately assessed using accelerometry-based wearable motion detectors for physical activity monitoring in post-stroke patients in the subacute phase?
- 25 October 2017
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Preventive Cardiology
- Vol. 24 (18) , 2009-2016
Abstract
In the subacute stroke phase, the monitoring of ambulatory activity and activities of daily life with wearable sensors may have relevant clinical applications. Do current commercially available wearable activity trackers allow us to objectively assess the energy expenditure of these activities? The objective of the present study was to compare the energy expenditure evaluated by indirect calorimetry during the course of a scenario consisting of everyday activities while estimating the energy expenditure using several commercialised wearable sensors in post-stroke patients (less than six months since stroke). Twenty-four patients (age 68.2 ± 13.9; post-stroke delay 34 ± 25 days) voluntarily participated in this study. Each patient underwent a scenario of various everyday tasks (transfer, walking, etc.). During the implementation, patients wore 14 wearable sensors (Armband, Actigraph GT3X, Actical, pedometer) to obtain an estimate of the energy expenditure. The actual energy expenditure was concurrently determined by indirect calorimetry. Except for the Armband worn on the non-plegic side, the results of our study show a significant difference between the energy expenditure values estimated by the various sensors and the actual energy expenditure when the scenario is considered as a whole. The present results suggest that, for a series of everyday tasks, the wearable sensors underestimate the actual energy expenditure values in post-stroke patients in the subacute phase and are therefore not accurate. Several factors are likely to confound the results: types of activity, prediction equations, the position of the sensor and the hemiplegia side.Keywords
This publication has 31 references indexed in Scilit:
- Activity Recognition Using a Single Accelerometer Placed at the Wrist or AnkleMedicine & Science in Sports & Exercise, 2013
- Measuring Energy Expenditure After StrokeStroke, 2012
- Laboratory and field methods for measuring human energy expenditureAmerican Journal of Human Biology, 2012
- Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis systemEuropean Journal of Applied Physiology, 2011
- Measurement properties of the SenseWear armband in adults with chronic obstructive pulmonary diseaseThorax, 2010
- Monitoring of Physical Activity After Stroke: A Systematic Review of Accelerometry-Based MeasuresArchives of Physical Medicine and Rehabilitation, 2010
- Accelerometer monitoring of home- and community-based ambulatory activity after stroke11A commercial party with a direct financial interest in the results of the research supporting this article has conferred or will confer a financial benefit on the author or 1 or more of the authors.Archives of Physical Medicine and Rehabilitation, 2004
- Évaluation clinique de la marche de l'hémiplégique vasculaire : proposition d'une modification de la functional ambulation classificationAnnales de Réadaptation et de Médecine Physique, 2000
- Prevalence and Associated Features of the Cold Hemiplegic ArmStroke, 1995
- Motor Evaluation in Vascular HemiplegiaEuropean Neurology, 1980