Impact of the gradient in gantry‐table rotation on dynamic trajectory radiotherapy plan quality
Open Access
- 25 September 2023
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 50 (11) , 7104-7117
Abstract
Background: To improve organ at risk (OAR) sparing, dynamic trajectory radiotherapy (DTRT) extends VMAT by dynamic table and collimator rotation during beam‐on. However, comprehensive investigations regarding the impact of the gantry‐table (GT) rotation gradient on the DTRT plan quality have not been conducted.Purpose: To investigate the impact of a user‐defined GT rotation gradient on plan quality of DTRT plans in terms of dosimetric plan quality, dosimetric robustness, deliverability, and delivery time.Methods: The dynamic trajectories of DTRT are described by GT and gantry‐collimator paths. The GT path is determined by minimizing the overlap of OARs with planning target volume (PTV). This approach is extended to consider a GT rotation gradient by means of a maximum gradient of the path () between two adjacent control points () and maximum absolute change of G (). Four DTRT plans are created with different maximum G&∆G: & = 0.5&0.125 (DTRT‐1), 1&0.125 (DTRT‐2), 3&0.125 (DTRT‐3) and 3&1(DTRT‐4), including 3–4 dynamic trajectories, for three clinically motivated cases in the head and neck and brain region (A, B, and C). A reference VMAT plan for each case is created. For all plans, plan quality is assessed and compared. Dosimetric plan quality is evaluated by target coverage, conformity, and OAR sparing. Dosimetric robustness is evaluated against systematic and random patient‐setup uncertainties between in the lateral, longitudinal, and vertical directions, and machine uncertainties between in the dynamically rotating machine components (gantry, table, collimator rotation). Delivery time is recorded. Deliverability and delivery accuracy on a TrueBeam are assessed by logfile analysis for all plans and additionally verified by film measurements for one case. All dose calculations are Monte Carlo based.Results: The extension of the DTRT planning process with user‐defined to investigate the impact of the GT rotation gradient on plan quality is successfully demonstrated. With increasing , slight (case C, : up to−1Gy) and substantial (case A, : up to −9.3 Gy, caseB,: up to −4.7Gy) improvements in OAR sparing are observed compared to VMAT, while maintaining similar target coverage. All plans are delivered on the TrueBeam. Expected and actual machine position values recorded in the logfiles deviated by 96% (2%global/2 mm Gamma passing rate) with the dose calculation. With increasing , delivery time is prolonged by <2 min/trajectory (DTRT‐4) compared to VMAT and DTRT‐1. The DTRT plans for case A and B and the VMAT plan for case C plan reveal the best dosimetric robustness for the considered uncertainties.Conclusion: The impact of the GT rotation gradient on DTRT plan quality is comprehensively investigated for three cases in the head and neck and brain region. Increasing freedom in this gradient improves dosimetric plan quality at the cost of increased delivery time for the investigated cases. No clear dependency of GT rotation gradient on dosimetric robustness is observed.Keywords
Funding Information
- Varian Medical Systems
This publication has 32 references indexed in Scilit:
- 4π Noncoplanar Stereotactic Body Radiation Therapy for Head-and-Neck Cancer: Potential to Improve Tumor Control and Late ToxicityInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2015
- Noncoplanar beams improve dosimetry quality for extracranial intensity modulated radiotherapy and should be used more extensivelyMedical Physics, 2015
- Impact of plan parameters on the dosimetric accuracy of volumetric modulated arc therapyMedical Physics, 2013
- Clinical experience transitioning from IMRT to VMAT for head and neck cancerMedical Dosimetry, 2013
- 4π Non-Coplanar Liver SBRT: A Novel Delivery TechniqueInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- Volumetric modulated arc therapy: a review of current literature and clinical use in practiceBritish Journal of Radiology, 2011
- A new metric for assessing IMRT modulation complexity and plan deliverabilityMedical Physics, 2010
- Volumetric Intensity-Modulated Arc Therapy Vs. Conventional IMRT in Head-and-Neck Cancer: A Comparative Planning and Dosimetric StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Volumetric modulated arc therapy: IMRT in a single gantry arcMedical Physics, 2007
- A treatment planning study using non-coplanar static fields and coplanar arcs for whole breast radiotherapy of patients with concave geometryRadiotherapy and Oncology, 2007