An experimental method for calibration of the plasmon mean free path
- 18 November 2009
- journal article
- Published by Wiley in Journal of Microscopy
- Vol. 236 (3) , 165-173
Abstract
Summary: Transmission electron microscopy specimens in the form of elongated, conical needles were made using a dual‐beam focused ion beam system, allowing the specimen thickness to be geometrically determined for a range of thickness values. From the same samples electron energy loss maps were acquired and the plasmon mean free path (λ) for inelastic scattering was determined experimentally from the measured values of specimen thickness. To test the method λ was determined for Ni (174 ± 17 nm), α‐Al2O3 (143 ± 14 nm), Si (199 ± 20 nm) and amorphous SiO2 (238 ± 12 nm), and compared both to experimental values of λ taken from the literature and to calculated values. The calculated values of λ significantly underestimate the true sample thickness for high accelerating voltages (300 kV) and large collection angles. A linear dependence of λ on thickness was confirmed for t/λ < 0.5–0.6, but this method also provides an approach for calibrating λ at sample thicknesses for which multiple scattering occurs, thus expanding the thickness range over which electron energy loss spectroscopy can be used to determine the absolute sample thickness (t/λ > 0.6). The experimental method proposed in this contribution offers a means to calibrate λ for any type of material or phase that can be milled using a focused ion beam system.Keywords
This publication has 17 references indexed in Scilit:
- Maximum diameter of the rod-shaped specimen for transmission electron microtomography without the “missing wedge”Ultramicroscopy, 2008
- Determination of mean free path for energy loss and surface oxide film thickness using convergent beam electron diffraction and thickness mapping: a case study using Si and P91 steelJournal of Microscopy, 2006
- Investigation of Diffraction Condition and Convergent Probe Effects on Inelastic Mean Free Path Determination by Using a Cone-Shaped Silicon CrystalMicroscopy and Microanalysis, 2006
- Effect of diffraction condition on mean free path determination by EELSQJM: An International Journal of Medicine, 2001
- Absolute measurement of normalized thickness, t/λi, from off-axis electron holographyUltramicroscopy, 1994
- EELS log‐ratio technique for specimen‐thickness measurement in the TEMJournal of Electron Microscopy Technique, 1988
- Measurement of local thickness by electron energy-loss spectroscopyUltramicroscopy, 1987
- Foil thickness measurements from convergent-beam diffraction patterns An experimental assessment of errorsPhilosophical Magazine A, 1982
- Foil thickness measurements from convergent-beam diffraction patternsPhilosophical Magazine A, 1981
- Preparation of contamination-free tungsten specimens for the field-ion microscopeJournal of Scientific Instruments, 1967