Hybrid Synthetic Receptors on MOSFET Devices for Detection of Prostate Specific Antigen in Human Plasma
- 17 November 2016
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (23) , 11486-11490
Abstract
The study reports the use of extended gate field-effect transistors (FET) for the label-free and sensitive detection of prostate cancer (PCa) bio-markers in human plasma. The approach integrates for the first time hybrid synthetic receptors compris-ing of highly selective aptamer-lined pockets (apta-MIP) with FETs for sensitive detection of prostate specific antigen (PSA) at clinically relevant concen-trations. The hybrid synthetic receptors were con-structed by immobilising an aptamer-PSA complex on gold and subjecting it to 13 cycles of dopamine electropolymerisation. The polymerisation resulted in the creation of highly selective polymeric cavities that retained the ability to recognize PSA post removal of the protein. The hybrid synthetic receptors were subsequently used in an extended gate FET setup for electrochemical detection of PSA. The sensor was reported to have a limit of detection of 0.1 pg/ml with a linear detection range from 0.1 pg/ml to 1 ng/ml PSA. Detection of 1-10 pg/mL PSA was also achieved in diluted human plasma. The present apta-MIP sensor developed in conjunction with FET devices demonstrates the potential for clinical application of synthetic hybrid receptors for the detection of clinically relevant biomarkers in complex samples.Keywords
This publication has 23 references indexed in Scilit:
- Extended-gate field-effect transistor (EG-FET) with molecularly imprinted polymer (MIP) film for selective inosine determinationBiosensors and Bioelectronics, 2015
- Label‐Free Sensing of Biomolecules with Field‐Effect Devices for Clinical ApplicationsElectroanalysis, 2014
- Label-Free Sub-picomolar Protein Detection with Field-Effect TransistorsAnalytical Chemistry, 2010
- Ion-Sensitive Field-Effect Transistor for Biological SensingSensors, 2009
- Label-Free Protein Biosensor Based on Aptamer-Modified Carbon Nanotube Field-Effect TransistorsAnalytical Chemistry, 2006
- Chemical and biological sensors using polycrystalline silicon TFTsJournal of Materials Chemistry, 2006
- Labelfree fully electronic nucleic acid detection system based on a field-effect transistor deviceBiosensors and Bioelectronics, 2004
- Tailored Chemosensors for Chloroaromatic Acids Using Molecular Imprinted TiO2Thin Films on Ion-Sensitive Field-Effect TransistorsAnalytical Chemistry, 2000
- Molecularly Imprinted Polymers and Their Use in Biomimetic SensorsChemical Reviews, 2000
- A miniaturized urea sensor based on the integration of both ammonium based urea enzyme field effect transistor and a reference field effect transistor in a single chipTalanta, 1999