Abstract
Investigations are presented on particle separation in impactors, sampling cyclones and other precollectors. These devices are increasingly used for the characterization of particulate matter. Size selective samplers must be characterized by their grade efficiency curves. A new measuring procedure is presented, which permits the determination of the grade efficiency curves of various sampling devices. An optical particle counter and a vibrating orifice generator are used in these measurements. This calibration technique is fast and has a high resolution. Investigations were carried out on the influence of various parameters on the classification efficiency of impactors and sampling cyclones. Using the extensive data measured a better understanding and quantification of impactor and cyclone behaviour is developed which may improve their applications in particle sampling.

This publication has 3 references indexed in Scilit: